STA-RITE DURA-JET 5JSAC-A Owner'S Manual Download Page 8

8

PUMP SERVICE

Pump should only be serviced by qualified personnel.

To avoid dangerous or fatal electrical shock hazard, disconnect power
to motor before working on pump or motor!

No lubrication or regular maintenance are needed.

If shaft seal is damaged, repair as follows:

Removing Old Seal:

1. Disconnect power to pump motor.

2. Drain spa and pump; disconnect unions to allow access to pump.

3. Remove six bolts holding front plate to seal plate; remove front plate.

4. Remove shaft cover or motor canopy; using screwdriver in slot on motor

end of shaft or wrench on flats of shaft extension, hold pump shaft and un-
screw impeller from shaft (turn counterclockwise). Rotating half of seal will
come off with impeller.

5. Carefully remove rotating part of seal from impeller sleeve by pulling and

turning on sealing washer and spring (Figure 2). Do not damage impeller
surface where drive ring seats and seals.

6. Carefully remove four motor throughbolts from seal plate (Figure 3); remove

seal plate and use a screwdriver to tap ceramic seat out from the rear
(Figure 4). Do not damage seal cavity in seal plate.

7. Clean cavity from which seal was removed and clean motor shaft.

Installing New Seal:

1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet rubber

cup gasket of ceramic seat with 

small

amount of liquid detergent; press into

cavity firmly and squarely with finger pressure (Figure 5).

2. If ceramic seat will not locate properly, remove it, place 

face up 

on bench,

and reclean cavity. Ceramic seat should now locate.

3. Seal must be free of dirt, grease, grit, scratches or chips; be sure impeller

sleeve is clean. Slide seal assembly, rubber drive ring first, onto impeller
sleeve until drive ring bottoms on impeller back shroud.

4. Slip slinger over shaft; remount seal plate. Torque throughbolts to 25 inch-

lbs. (29 cm-kg).

Hazardous voltage.
Can shock, burn,
or cause death.

Disconnect power
before working
on pump or motor.

Figure 2

Figure 3

Figure 4

Figure 5

Summary of Contents for DURA-JET 5JSAC-A

Page 1: ...ite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga Ont Murrieta CA 2005 Sta Rite Industries S223 Rev...

Page 2: ...CAREFULLY The Sta Rite JS Series Spa Pump Is designed to circulate hot water in spas and hot tubs Is an excellent performer durable reliable Table of Contents Safety Instructions 3 Installation 4 Elec...

Page 3: ...Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional per form all pressure tests 1 Do not connect system to a high pressure or city w...

Page 4: ...compartment Piping Use flexible or rigid PVC pipe for connections to pump Suction discharge piping gate valves will allow removal for servicing Use at least 1 1 2 48mm IPS pipe Fittings restrict flow...

Page 5: ...AWG 8 4mm2 or larger Wiring Pump must be permanently connected to circuit Table I Page 6 gives correct wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the s...

Page 6: ...1 Lo Hi Timer Motor Supply Lo Hi Circuit Protector Remote SPDT Switch Ground Green Common Remote Switching For 2 Speed Pumps Timer optional Low Speed Only Minimum switch and timer amp rating must equa...

Page 7: ...ng when system is not in use Failure to do so can allow air to enter system causing pump to lose its prime Keep water temperature at 104 F 40 C or below Age or health conditions may require a lower te...

Page 8: ...e ring seats and seals 6 Carefully remove four motor throughbolts from seal plate Figure 3 remove seal plate and use a screwdriver to tap ceramic seat out from the rear Figure 4 Do not damage seal cav...

Page 9: ...f possible store chemicals in another room Allowing pump to freeze will damage pump and void warranty Drain all water from pump and piping when expecting freezing temperatures or when storing pump for...

Page 10: ...t the low point of the spa piping to help drain spa system 6 Before restarting replace all plugs and make sure all pipe connections are tightly sealed Startup For Winterized Equipment 1 Remove any tem...

Page 11: ...use poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2 51 mm above top of jets w...

Page 12: ...YD A 3 4 C218 299 C105 229PA Key Part No Description Qty Number 1 Motor 1 Chart at Right 2 Slinger 1 C69 23 3 Collar Union 2 U11 182P1 4 Adapter Union 2 U11 183P1 5 O Ring 2 U9 226P 6 Seal Plate 1 C1...

Reviews: