ELECTRICAL

Ground motor before connecting to electrical power supply! Failure to
ground pump motor can cause serious or fatal electrical shock hazard!

Do not ground to a gas supply line!

To avoid dangerous or fatal electrical shock, turn OFF power to motor
before working on electrical connections.

GFCI tripping indicates an electrical problem. If GFCI trips and will not
reset, have a qualified electrician inspect and repair electrical system.

Exactly match supply voltage to nameplate voltage (230 Volt, 50Hz,
single phase only)! Incorrect voltage can cause fire or seriously

damage motor and voids warranty!

Grounding:

Install, ground, and wire motor according to local or National Electrical Code
requirements.
Permanently ground motor; use size and type wire required by code.
Ground connection must be made to green grounding terminal under motor
canopy or access plate (see Figure 1).
Connect motor ground terminal to electrical service ground.
Install and bond pump according to local codes and ordinances; use bonding
lug on motor (see Figure 1). Use solid copper conductor No. 8 AWG (8.4mm

2

)

or larger.

Wiring:

Pump must be permanently connected to circuit. Table I, Page 6, gives correct
wire and circuit breaker sizes for the pump alone. If other lights or appliances
are also on the same circuit, be sure to add their amp loads to pump amp load
before figuring wire and circuit breaker sizes. (If unsure how to do this or if
this is confusing, consult a licensed electrician.) Use the load circuit breaker
as the master on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-
circuit to ground and disconnect power before it becomes dangerous to pool
users. For size of GFCI required and test procedures for GFCI, see manufac-
turer’s instruction.
In case of power outage, check GFCI for tripping (which will prevent normal
pump operation). Reset if necessary. 

NOTICE: 

If you do not use conduit when wiring motor, 

be sure

to seal wire

opening on end of motor to prevent dirt, bugs, etc., from entering.

Hazardous voltage.
Can shock, burn,
or cause death.

Ground pump before
connecting to
power supply.

BONDING

LUG

MOTOR NAMEPLATE

GREEN

GROUND

SCREW

MOTOR

CANOPY

THROUGH

BOLTS

499 0993

Figure 1A: Typical ground screw and
bonding lug locations.

White

230
Volt
Lines

A

B

L2

L1

Blue

Figure 1B. Motor terminal block
connections.

230 Volt Hookup

Summary of Contents for DURA-JET 5JSAC-A

Page 1: ...ite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga Ont Murrieta CA 2005 Sta Rite Industries S223 Rev...

Page 2: ...CAREFULLY The Sta Rite JS Series Spa Pump Is designed to circulate hot water in spas and hot tubs Is an excellent performer durable reliable Table of Contents Safety Instructions 3 Installation 4 Elec...

Page 3: ...Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional per form all pressure tests 1 Do not connect system to a high pressure or city w...

Page 4: ...compartment Piping Use flexible or rigid PVC pipe for connections to pump Suction discharge piping gate valves will allow removal for servicing Use at least 1 1 2 48mm IPS pipe Fittings restrict flow...

Page 5: ...AWG 8 4mm2 or larger Wiring Pump must be permanently connected to circuit Table I Page 6 gives correct wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the s...

Page 6: ...1 Lo Hi Timer Motor Supply Lo Hi Circuit Protector Remote SPDT Switch Ground Green Common Remote Switching For 2 Speed Pumps Timer optional Low Speed Only Minimum switch and timer amp rating must equa...

Page 7: ...ng when system is not in use Failure to do so can allow air to enter system causing pump to lose its prime Keep water temperature at 104 F 40 C or below Age or health conditions may require a lower te...

Page 8: ...e ring seats and seals 6 Carefully remove four motor throughbolts from seal plate Figure 3 remove seal plate and use a screwdriver to tap ceramic seat out from the rear Figure 4 Do not damage seal cav...

Page 9: ...f possible store chemicals in another room Allowing pump to freeze will damage pump and void warranty Drain all water from pump and piping when expecting freezing temperatures or when storing pump for...

Page 10: ...t the low point of the spa piping to help drain spa system 6 Before restarting replace all plugs and make sure all pipe connections are tightly sealed Startup For Winterized Equipment 1 Remove any tem...

Page 11: ...use poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2 51 mm above top of jets w...

Page 12: ...YD A 3 4 C218 299 C105 229PA Key Part No Description Qty Number 1 Motor 1 Chart at Right 2 Slinger 1 C69 23 3 Collar Union 2 U11 182P1 4 Adapter Union 2 U11 183P1 5 O Ring 2 U9 226P 6 Seal Plate 1 C1...

Reviews: