DC and AC Parameters
STM1061
14/23
6
DC and AC Parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 4: Operating and AC Measurement Conditions
. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Figure 15.
AC Testing Input/Output Waveforms
Table 4.
Operating and AC Measurement Conditions
Sym Parameter
STM1061
Unit
V
CC
Supply Voltage
0.7 to 6.0
V
T
A
Ambient Operating Temperature
–40 to 85
°C
Input Rise and Fall Times
≤
0
5
ns
Input Pulse Voltages
0.2 to 0.8V
CC
V
Input and Output Timing Ref. Voltages
0.3 to 0.7V
CC
V
AI02568
0.8VCC
0.2VCC
0.7VCC
0.3VCC