DC and AC Parameters
STM1061
16/23
Table 5.
DC and AC Characteristics
Sym.
Description
Test Condition
(1)
1.
Valid for Ambient Operating Temperature: T
A
= 25°C.
Min
Typ
Max
Unit
V
CC
Operating Voltage
0.7
6.0
V
I
CC
V
CC
Supply Current
V
CC
= 3.0V, No Load
0.9
3.0
µA
V
CC
= 5.5V, No Load
1.1
3.6
µA
I
OUT
Output Current, N-channel
(V
DS
= 0.5V),
Reset asserted
V
CC
= 1.0V
1.0
1.7
mA
V
CC
= 2.0V
3.0
14
mA
V
CC
= 3.0V
5.0
22
mA
V
CC
= 4.0V
6.0
26
mA
V
CC
= 5.0V
7.0
30
mA
Voltage Thresholds
V
TH–
Detect Voltage
(2)
(see
Table 9 on page 21
for
detailed listing)
2.
Other V
TH-
threshold are offered. Minimum order quantities may apply. Contact local sales office for availability.
V
TH–
– 2%
V
TH–
V
TH–
+ 2%
V
V
TH+
Release Voltage
V
TH–
+
V
HYST
V
V
HYST
Threshold Hysteresis
0.02
V
TH–
0.05
V
TH–
0.08
V
TH–
V
t
PD
V
CC
to OUT Detect Delay
V
CC
falling from (V
TH–
+ 100mV) to (V
TH–
–
100mV)
at 10mV/µs
25
µs
t
PR
V
CC
to OUT Release Delay
V
CC
rising from (V
TH+
– 100mV) to (V
TH+
+
100mV)
at 10mV/µs
30
200
µs
Threshold Temperature
Coefficient
±100
ppm/
o
C