![ST STEVAL-ISF003V1 User Manual Download Page 28](http://html1.mh-extra.com/html/st/steval-isf003v1/steval-isf003v1_user-manual_1356008028.webp)
Mains
voltage dips and interruptions
UM2076
28/43
DocID029457 Rev 1
In the former, the SCRs are kept ON during the line interrupt. When the voltage is
reapplied, the peak current is only 30 A as the DC voltage only decreased by 60 V during
the lack of AC voltage. Only the SCR1 control is defined in this waveform.
Figure 19: Board operation during 1-cycle line interruption