AN2451
Board description
Doc ID 12791 Rev 3
25/55
Figure 16.
Measured input impedance magnitude of coupling interface in Tx mode
(typical curve)
Figure 17.
Measured input impedance magnitude of coupling interface in Rx mode
(typical curve)
5.2 Conducted
disturbances
5.2.1 Conducted
emissions
The EN50065-1 standard describes the test setup and procedures for testing conducted
emissions.
The conducted emissions measurements have been taken with 220 V
ac
mains voltage. The
test pattern consists of a continuous transmission of a “1010” continuous sequence at 2400
baud, deviation 1. The output signal measured at the CISPR artificial network has a value of
120 dBuV
RMS
which means a signal of 2 V
RMS
on the mains output.