Installation process:
1.
Fasten girder clamp with eye eye on the threaded rod (M16) according to
Figure 1
. Tighten the nuts on both sides with a torque of 105 Nm.
Figure 1
2.
Attach second girder clamp together with the nuts and washers on the threaded rod
according to
Figure 2
. (Do not tighten lock nut yet.)
Figure 2
Torque
105 Nm