
ST QUADRAT Fall Protection S.A.
–
Your competent partner for fall protection
–
www.lux-top-absturzsicherungen.de
page 8 version 07/2019
Installation information
LUX-top
®
QUICKFIX II
Minimum requirement of the substructure:
Before installing the anchor device, the load-bearing capacity of the steel structure must be
checked. The technical building regulations must be complied with. Only original parts belonging to
the anchor point system may be used.
I-beam with the following cross-section values
min. b
100 mm*
max. b
200 mm
min. t
8 mm
max. t
15 mm
*Exceptions are possible after consultation with the manufacturer
Installation position
Installation can take place on steel beams arranged horizontally, vertically and at any
angle.