Greenfield Installation and Operations Stove
Page 47
8.
Are there any adjustments that can be made, through the control board, to the amount
of fuel that is fed into the burnpot?
Answer: There are several ways to adjust the amount of fuel that
is fed into the burnpot. The Feed Rates can be fine-tuned while
the Stove is in operation by
pressing and holding
the “Auger
Feed” button down and then
either
pressing the “Heat Level
High” button to advance the feedrate higher,
or
pressing the
“Heat Level Low” button to decrease the feedrate.
There are 5 levels on the control board and they are indicated by
a single flash of the LED’s. The default setting is the center
LED. This gives 2 adjustments increasing the Feed Rate (LED’s
4 & 5) and 2 adjustments decreasing the Feed Rates. (LED’s 1 &
2) The ON time is
increased or decreased
.25 seconds with each
adjustment.
Figure 31
9.
Are there any adjustments that can be made, through the control board, to the
Combustion Fan voltages to help adjust the draft?
Answer: The Draft can be adjusted in a similar fashion as
mentioned in the previous example.
The Fan voltages can be fine-tuned while the Stove is in
operation by
pressing and holding
the “Auger Feed” button
down and then
either
pressing the “Trim High” button to
advance the voltages higher,
or
pressing the “Trim Low” button
to decrease the fan voltages.
There are 5 levels on the control board and they are indicated by
single flash of the LED’s. The default setting is the center LED.
This gives 2 adjustments increasing the voltage (LED’s 4 & 5)
and 2 adjustments decreasing the voltage. (LED’s 1 & 2) The
voltage is
increased or decreased
2.5 volts with each adjustment.
Figure 32