Greenfield Installation and Operations Stove
Page 27
1.
The Heat Level button will advance the setting up and down between level 1 and 5. It will
also be used in the Fine Tuning process of the feed rates if needed.
a.
To adjust the Feed-rates: Hold the Auger Feed Button down and press the Heat Level
High/Low button and this will change the ON Time up or down .25 seconds from the factory
setting. Watch the LED lights to see the setting is on (it will flash the new setting). This new
setting will stay in memory from this point on.
2. The Auger Feed button will allow the user to manually auger fuel into the burn pot on start
up when needed. This is particularly helpful in priming the Auger Tube when it is empty (After
the hopper has run out of fuel).
Do not tamper with the Auger Feed button to override the
automated feed system. This may cause the unit to Overheat.
To adjust the Feed-rates:
Hold the Auger Feed Button down and press the Heat Level High/Low button and this
will change the ON Time up or down .25 seconds from the factory setting. Watch the
LED lights to see the setting is on (it will flash the new setting). This new setting will
stay in memory from this point on.
3. The On/Off button not only turns the Stove On and Off, it also resets the board if one of the
sensors has detected a problem and the board is flashing a Diagnostic code.
4. The Draft Trim button allows for adjusting the Exhaust (Combustion) fan voltages up or
down providing for fine-tuning of the combustion air. The LED light bar indicates the level of
adjustment and the factory setting is the center LED light. This allows for 2 adjustments up and 2
adjustments down. (See point 9 on page 48)
To adjust the Combustion Fan voltages:
Hold the Auger Feed button down and press the Draft Trim High/Low button and this will
change the fan voltage approximately 2.5 volts up or down from the factory setting. Watch
the LED lights to see the setting is on (it will flash the new setting). This new setting will
stay in memory from this point on.
5. The Thermostat Slide switch allows the Stove to be run in 3 different Modes:
a.
Manual Mode
. The Control Board controls all functions of the Greenfield.
b.
T-Stat Mode
. The Multi-Fuel Stove is hooked to a Thermostat and when calling for heat
the Greenfield will advance to the Heat level set at the Control board. Once the Heat demand
has been met the Stove will drop to the #1 Heat Level setting and pilot. The Stove never
shuts off and provides constant heat.
c.
SmartStat Mode
.
Do not use this setting with the Greenfield.
This Thermostat mode
may only be used with Pellets in a unit with the Versa Grate System & Igniter installed
Pre-Lighting Instructions
The Control Board has 4 separate program-. Two of the programs are for the Greenfield
(Programs 1 & 2) and two of the programs are for the Prescott EXP and Prescott EXL (Programs
3 & 4). Before lighting the Stove for the first time, ask your dealer about how to change the