Element-MF Stove
13
VENTING: TERMINATION REQUIREMENTS
In determining optimum vent termination, carefully evaluate external conditions especially when
venting directly through a wall. Since you must deal with odors, gases, and fly ash, consider
aesthetics, prevailing winds, distances from air inlets and combustibles, location of adjacent
structures and any code requirements.
1. Exhaust must terminate above combustion air inlet elevation.
2. Do not terminate vent in any enclosed or semi-enclosed area, (i.e. Carports, garage, attic
crawl space, etc.) or any location that can build up a concentration of fumes.
3. Vent surfaces can get hot enough to cause burns if touched by children. Non-combustible
shielding or guards may be required
The type of installation must first be considered before determining the exact location of
the venting termination in relation ship to doors, window, cavities or air vents.
a.
Without
Outside Air connected to the unit. For this types of installation please refer to
the dimensions listed below in figure 4.
Figure 4
4’ (1.2 m) BELOW
a door, window, cavity, or air vent
Or
4’ (1.2 m) HORIZONTALLY FROM
a door, window, cavity, or air vent
Or
1’ (305 mm) ABOVE
a door, window, cavity, or air vent
Summary of Contents for Element-MF
Page 56: ...Element MF Stove 56 Figure 37 Element MF Parts ...
Page 57: ...Element MF Stove 57 Figure 38 Element MF Parts ...
Page 58: ...Element MF Stove 58 Figure 39 Element MF Parts ...
Page 59: ...Element MF Stove 59 Figure 40 Figure 41 Element MF Parts ...
Page 60: ...Element MF Stove 60 Sensor System Figure 42 Figure 43 Figure 44 Element MF Parts ...