31
Reserving bus addresses
As standard, the Gateway is
assigned one bus address in the
In-Home bus.
An IP user or an IP
group made up of at least 2 IP users
could then be called using this bus
address.
In order to allow add
itional IP users/
IP
groups (e.g. Siedle
app or bus
software in-house telephone)
to be
called separately via the In-Home
bus, the Gateway req
uires additional
In-
Home bus addresses.
For each IP user / group w
hich you
wish to cal
l separately, an additional
In-Home bus address must be
rese
rved via the Gateway.
Remark
:
Only freely available In-Home
bus addresses can b
e reserved. If
more In-Home bus addresses are
requested than are available, the
maximum quantity of free In-Home
bus addresses in the relevant bus line
are rese
rved in the Gateway.
Example:
At the Gateway, you a
re operating
one Sie
dle app for Gateway
and one
bus software in-house telephone.
Both IP users should be capable of
being
called separately.
For the Gateway, only on
e In-Home
bus addres
s would be assigned
as
standard.
This bus address could
therefore only be assigned to an IP
user or
to a group with seve
ral or
all IP users.
All other network users
would not b
e able to be called via
the In-Home bus.
Solution:
You will require an addi
tional
In-Home bus address in order to be
able to call both
IP users separately.
Procedure:
1
Log in to the Gateway.
2
Click on In-Home bus > bus
addresses.
3
Click on Reserve bus address(es).
4
Enter the number of bus addresses
y
ou wish to reserve.
5
Click on Apply in order to start the
r
eservation process.
6
In the header of the Gateway,
the fo
llowing message appe
ars:
Searching for reservable bus
addresses in the In-Home b
us. The
search can t
ake several minutes.
7
During the active search, the
In-Home LED flashes at the Gatewa
y
and the LED1 flashes on the BNG/
BVNG.
8
If the required number of In-Home
bus addresses has been reserved,
the fo
llowing message appe
ars:
Reservation suc
cessfully completed.
9 Start the programming mode
at the bus video
line rectifier,
and end it after 2 seconds at the
earliest.
10
The reserved In-Home bus
address(es
) has/have been assi
gned
to the Gateway
and can be used
for
programming/configur
ing the
In-Home bus.
11
Repeat the steps for program-
ming with P
C and Bus programming
software BPS 650-…
Optional commissioning steps
Import licences
There are 2 user licences for IP users
contained in the scop
e of supply.
For each IP user / IP group (Siedle
App for Sm
art Gateway or bus s
oft-
ware in-house telephone) you wish
to be able to call sepa
rately, you will
req
uire a user licence.
A telephony licence is required for
each c
onnected TC system.
A telephony licence is not included
in t
he scope of supply.
If you require additional licences,
these can be ordered from Siedle
(
www.siedle.de/mysiedle) and
imported int
o the Gateway.
Accessing is only possible subject to
prior p
roduct registration.
Remark:
To import the user licences, a licence
file is required with the file suffix
.xml.
Procedure:
1
Click on Network users > licences.
2
Click on Select file …
3
Select the licence file su
pplied by
Siedle (e.g. Lizenz_SG650.xml)
and
confirm your selection with Open.
4
Click on Upload file to import the
l
icence information.
5
After successful import of the
li
cence file, a confir
mation appears
and the number of licences has
changed.
6
Hand
over the licence fil
e to your
customer/s
ystem administrator.