54
7 Servicing
Measured values
Measured values in the 1+n system, for measurement using a digital multimeter
Idle status
Voltage door station
Terminal 1 and 7…
Voltage in-house telephone
Terminal 1 and 7
Description
22–24 V DC
0 V DC
No in-house telephone connected, core interrupted,
in-house telephone defective.
17–19 V DC
17–19 V DC, 50 µA
OK In-house telephone is in the idle status.
14–16 V DC
14–16 V DC, 50 µA 14–16 V
DC, >10 mA
Te at call button module or diode accessory missing
In-house telephone has already been called and is active
<14 V DC
<14 V DC
Cores to in-house telephone under load or
connected to an external device
Call status
Voltage door station
Terminal 1 and 7…
Voltage in-house telephone
Terminal 1 and 7
Description
22–24 V DC, 150 mA
>18 V DC, max. 150 mA
OK
24 V DC
---
No in-house telephone connected
<8 V DC
0 V
Short circuit between terminal 1 and 7
In-house telephone active/speech operation
Voltage door station
Terminal 1 and 7…
Voltage in-house telephone
Terminal 1 and 7
Description
22-24 V DC
---
No in-house telephone connected
16–18 V DC
16–18 V DC, 50 µA 16–18 V
DC, 50 µA
In-house telephone has not been called from the door
Last door call longer than 30 seconds ago
14–16 V DC
14–16 V DC, >10–15 mA
OK,
receiver not lifted within 30 seconds after call
14–16 V DC
14–16 V DC, >20 mA
OK, speech connection exists
<14 V DC
<14 V DC
Cores to in-house telephone under load or connected to
an external device
Intercom system with more than 1 door station
Voltage door station terminal TLn and –
Description
appr. 6 V DC
OK
Connection to SFC 602-… or CTÖ 602-…
Voltage door station
D+ and D–
Voltage SFC/CTÖ
Terminal D+ and D–
Description
appr. 14 V DC
appr. 14 V DC
Connecting cores D+/D-
OK
appr. –14 V DC
appr. –14 V DC
SFC/CTÖ not responding, D+/D– cores interchanged
appr. –14 V DC
0 V
SFC/CTÖ not responding, D+/D– cores interrupted
0 V
0 V
SFC/CTÖ not responding, D+/D– cores short circuited
Summary of Contents for AS-Ta-64/1
Page 1: ...System Manual 1 n technology Issue 2013 ...
Page 7: ...7 ...
Page 16: ...16 5 Installation AS Ta 64 1 Siedle Vario Remarks Appliance requirement ...
Page 20: ...20 5 Installation AS Ta 64 1 Siedle Classic Remarks Buttons Appliance requirement ...
Page 22: ...22 5 Installation AS Ta 64 1 Siedle Steel Remarks Buttons Appliance requirement ...
Page 26: ...26 5 Installation AS Ta 64 2 Siedle Vario with 2 door stations Remarks Appliance requirement ...
Page 30: ...30 5 Installation AS Ta 64 3 Siedle Vario with 3 door stations Remarks Appliance requirement ...
Page 53: ...53 ...