INS-TSSHC-3NPSBFS-16A-1209
5
3. Using a screwdriver, loosen the screw retaining the mount ing
base and front part of the thermostat. Remove the front part
of the thermostat from the mounting base by tilting it upward.
4. Align and secure the mounting base to the connection box
using the two screws supplied.
5. Route wires coming from the wall through the hole of the
mounting base and make the required connections using
the “Four-wire installation” figure, and using the supplied
solderless connectors. A pair of wires (black) must be con-
nected to the power source (120-208-240 VAC) and an other
pair (yellow) must be connected to the heating cable (refer to
the drawings displayed on the back of the thermo stat). For
connections with aluminum wires, you must use CO/ALR