background image

INS-TSSHC-3NPSBFS-16A-1209

15

Backlighting

The  screen  lights  up  when  you  press  down  a  button.  If  you 

do not press down any button for more than 15 seconds, the 

screen turns off.

N.B.

 If you press down the + or – button once when the back light 

is off, it will light up without changing the set point value. The 
set point value will change only if you press down one of these 
buttons again.

Ground-fault Circuit Interrupter (GFCI)

The  GFCI  is  designed  to  reduce  the  risk  of  electric  shock.  It 

can detect a leakage current of 5 mA. If a defect is detect ed, 

the GFCI device lights up, and both screen and heating system 

circuit are deactivated. The GFCI can be reinitialized either by 

pressing down the Test button or by disconnecting the thermo-

stat at the electrical panel.

Ground-fault circuit interrupter (GFCI) verification

It  is  important  to  verify  the  ground-fault  circuit  interrupter  in-

stallation and operation on a monthly basis.

GFCI verification procedure

1- Increase  the  temperature  set  point  until  the  heating  power 

bars are displayed (displayed beside the floor tempera ture).

2- Press down the Test button.
3- The following two cases can occur:

a) Successful test: The red indicator of the thermostat lights 

up.  In  this  case,  press  down  once  again  the  Test  button 
to  reinitialize  the  ground-fault  circuit  interrupter,  the  red 
indicator turns off.

b) Failed  test:  The  red  indicator  does  not  light  up  and  the 

entire  display  blinks  during  5  seconds.  In  this  case,  dis-
connect the heating system at the electrical panel.

Summary of Contents for TSSHC-3NPSBFS-16A

Page 1: ...SSHC 3NPSBFS 16A 1209 For further information or to consult this guide on line please visit our Web site TSSHC 3NPSBFS 16A Heating floor non programmable electronic thermostat User s guide www sshcinc...

Page 2: ...der to avoid personal injuries or proper ty damages serious injuries and potential ly fatal electric shocks All electric connections must be made by a qualified electrician accord ing to the electrica...

Page 3: ...y have to press down the A F button to switch from one mode to the other This control method is ideal when you want a stable ambi ent air temperature without fluctuation Usually this mode is used in l...

Page 4: ...he examples that follow Do not install the thermostat in a location where temperature measurements could be altered For example close to a window on an external wall or close to a door leading outside...

Page 5: ...g the two screws supplied 5 Route wires coming from the wall through the hole of the mounting base and make the required connections using the Four wire installation figure and using the supplied sold...

Page 6: ...e sensor Four wire installation 6 Reinstall the front part of the thermostat on the mounting base and tighten the screw at the bottom of the unit 7 Turn on the power 8 Set the thermostat to the desire...

Page 7: ...d the standard factory set point adjustment is 77 F 25 C The maximum floor temperature is limited to 82 F 28 C Maximum floor temperature limitation At any time the floor temperature both in Floor and...

Page 8: ...um floor temperature set is 82 F 28 C In Day mode you can turn off the thermostat by lowering the set point below 37 F 3 C The set point value displayed will be OFF and heating system start up will be...

Page 9: ...own the and buttons and release them immediately Night mode timer The Night mode features a timer that automatically returns to the Day mode after a selectable time period This timer allows the tempor...

Page 10: ...button to decrease it The adjustment range is from 1 hour to 999 hours To quickly scroll through timer values press and hold down the but ton 4 When the adjustment is completed release the buttons an...

Page 11: ...8 hours at the night temperature set point Then it will return to the Day mode for 16 hours operating at the day temperature set point At the end of the 24 hour cycle the thermostat will return to the...

Page 12: ...o activate the Automatic mode and if it was activated the Automatic mode will be deacti vated 3 Activate the Automatic mode by simultaneously pressing down the and buttons for at least 3 seconds The A...

Page 13: ...tton to switch from the degrees Fahrenheit to the degrees Celsius and conversely The degree Fahrenheit or Celsius symbol is displayed 3 When the adjustment is completed do not press down any button du...

Page 14: ...ing cable This feature allow to decrease the measured temperature by 0 F to 18 F 0 C to 10 C by incre ment of 1 C To do so you must 1 Press down the A F button for at least 30 seconds the actual value...

Page 15: ...itialized either by pressing down the Test button or by disconnecting the thermo stat at the electrical panel Ground fault circuit interrupter GFCI verification It is important to verify the ground fa...

Page 16: ...note that the SET icon will also blink after 3 seconds 3 Release the buttons The thermostat is now locked Lock deactivation 1 Cut off the power supply of the thermostat at the electrical panel 2 Wait...

Page 17: ...timer which are saved only if the Automatic mode was not activated Please note that the Automatic mode is not automatically reac tivated when the power is restored the Automatic icon blinks to indica...

Page 18: ...Heating is al ways on Check if the thermostat is properly connect ed Refer to the installation section 3 Heating does not run even if the ther mostat indicates it is on Check if the thermostat is pro...

Page 19: ...load 16 A 3840 W 240 VAC 3475 W 208 VAC 1920 W 120 VAC Range of temperature 32 F to 99 F 0 C to 40 C Temperature display resolution 1 F 1 C Range of the temperature set points Ambient Mode 37 F to 95...