Limited Warranty

This unit has a 1 year warranty. If at any 

time during this period the unit becomes 

defective, return it to its place of purchase 

with a copy of the invoice, or contact 

our  customer  service  department  (with 

a  copy  of  the  invoice  in  hand). 

In order 

for the warranty to be valid, the unit 

must be installed and used according 

to instructions.

 If the installer or the 

user  modifies  the  unit,  they  will  be  held 

responsible for any damage resulting from 

this  modification.  The  warranty  is  limited 

to the factory repair or the replacement of 

the unit, and does not cover the cost of 

disconnection, transport, and installation.

Customer service

SSHC, Inc. 

P.O. Box 769 

Old Saybrook, CT 06475 

(860) 399-5434

www.sshcinc.com

Summary of Contents for TSSHC-3DNPSB-16A-115F

Page 1: ...NS TSSHC 3DNPSB 16A 115F 1210 For further information or to consult this guide on line please visit our Web site www sshcinc com TSSHC 3DNPSB 16A 115F Electronic thermostat User s guide www sshcinc co...

Page 2: ...uries or property damages serious injuries and potentially fatal electric shocks All electric connections must be made by a qualified electrician according to the electric and building codes effective...

Page 3: ...mable This product is designed for installations with electrical current with a resistive load ranging from 0 A to 16 A 90 VAC to 240VAC It possesses a user friendly interface Furthermore it gives you...

Page 4: ...ducts Do not install the thermostat in a location where temperature measurements could be altered For example close to a window on an external wall or close to a door leading outside exposed directly...

Page 5: ...r of any obstruction 3 Using a screwdriver loosen the screw retaining the mounting base and front part of the thermostat Remove the front part of the thermostat from the mounting base by tilting it up...

Page 6: ...e note that the thermostat wires do not have polarity Therefore the way they are connected is not important Four wire installation 6 Reinstall the front part of the thermostat on the mounting base and...

Page 7: ...set at 105 F 41 C by default Language English French To switch the display from English to French and conversely press down the backlit button for 20 seconds The display is set in English by default A...

Page 8: ...an also turn on the backlit screen by pressing down the backlit screen button Temperature set points The figures displayed below the SET pictogram indicate the temperature set point It can be displaye...

Page 9: ...n displays the word OFF Please note that when the word OFF is displayed the frost free minimum temperature feature is disabled Night mode timer The Night mode features a timer that automatically retur...

Page 10: ...the value or the button to decrease it The adjustment range is from 1 hour to 999 hours To quickly scroll through timer values press and hold down the button 4 When the adjustment is completed release...

Page 11: ...mode as soon as the Automatic mode is activated The Automatic mode activation should be made when you want to return to the Night mode The normal course of a cycle in the Automatic mode is as follows...

Page 12: ...it the adjustment function N B It is always possible to manually change the Day Night mode during a 24 hour cycle This will not change the 24 hour cycle and the automatic return to the Night mode Howe...

Page 13: ...will be displayed 3 When the adjustment is completed release the buttons and wait for 5 seconds to exit the adjustment function Temperature control The thermostat controls the temperature of the ambi...

Page 14: ...screen It s possible to adjust the lenght of the heating cycle from 480 seconds 8 minutes to 900 seconds 15 minutes Heating power indicator The level of power used to maintain the temperature at the...

Page 15: ...will find yourself in the degree adjustment mode or in Fan mode 3 The Lock icon will appear after 13 seconds indicating that the Lock mode is activated Release the buttons Procedures to deactivate th...

Page 16: ...ssed the SET icon will blink At this point release the buttons You must then press down the button to activate or deactivate the Fan mode The Fan icon will turn on or off depending on the case When Fa...

Page 17: ...the thermostat is turned on The icon for the automatization of the Day Night modes blinks to warn the user that the mode was previ ously activated when thermostat was shut off but is no lon ger active...

Page 18: ...he thermostat indicates it is on Check if the Load is correctly connected Refer to the installation section The display does not come on Check if the thermostat is correctly connected Refer to the ins...

Page 19: ...al current with a resistive load 16 A 3840 W 240 VAC 3330 W 208 VAC 1920 W 120 VAC Temperature display range 37 F to 140 F 3 C to 60 C Temperature display resolution 1 F 1 C Temperature set point rang...

Page 20: ...ce in hand In order for the warranty to be valid the unit must be installed and used according to instructions If the installer or the user modifies the unit they will be held responsible for any dama...