![SRS Labs GMC12-WL-12H6 Instruction Manual Download Page 8](http://html1.mh-extra.com/html/srs-labs/gmc12-wl-12h6/gmc12-wl-12h6_instruction-manual_1354204008.webp)
(8 /16)
EMERGENCY STOP:
E-STOP is a red color mushroom. Once the E-STOP button has been pressed, it locks the unit into
active position and must be rotated clockwise and released before disengaging. After engaging the
E-STOP button, the RESET button needs to be pressed to reset the system.
GO:
This green pushbutton turns the selected channels of Hoist Control system ON when is active. Once
the GO button has been depressed, the energizing of the hoists is turned OFF.
DIRECTION SWITCHES:
They allow changing the direction of movement for each motor/hoist separately or in groups. LED
close to the switch indicates the movement direction.
Charger status LED:
Status LED of charger located on the front panel is
Green:
Battery is fully charged
Green blinking:
Battery is charged to 90% or greater capacity
Orange blinking:
Not in rapid mode – waiting to be charged
Red:
Battery is in rapid charge mode
Red blinking:
Battery is ultra-rapid charge mode
No LED:
Battery is not inserted
Limit STOP input:
LIMIT STOP connectors for external E-STOP from NLP device.
Link input:
Link input for linking of GMC units.