6.3.2 Connecting AC Output
According to the cable sequence and terminal position shown in the figure below, correctly connect the AC
output cable. When wiring, please pay attention to L and N and avoid short-circuit.
6.3.3 Connecting Photovoltaic Input
According to the cable sequence and terminal position shown in the figure below, correctly connect the PV
input cable. When wiring, please pay attention to the positive and negative poles and avoid short-circuit.
6.3.4 Wiring specifications
Models
Recommended PV
wiring diameter
Recommended AC input
wiring diameter
Recommended AC output
wiring diameter
SR-EOV48-5.0S-C0
6mm
2
/10AWG
10mm
2
/7AWG
10mm
2
/7AWG
SR-EOV48-5.0U-C0
6mm
2
/10AWG
10mm
2
/7AWG
10mm
2
/7AWG