5. Product Specification Parameters
5.1 Electric Parameters
Parameter
Model
System voltage
No-load loss
Battery voltage
Max. solar input voltage
Max. power point voltage range
Rated charging current
Rated load current
Max. capacitive load capacity
Max. photovoltaic system input power
Conversion efficiency
MPPT tracking efficiency
Temperature compensation factor
Operating temperature
Waterproof level
Weight
Communication method
Altitude
Product dimensions
Value
ML4860N15
12V/24V/36V/48V Auto
12V/≤50mA;24V/≤25mA;36V/≤17mA;48V/≤13mA;
9V to 65V
150V (25°C), 145V (-25°C)
Battery v2V to 120V
60A
20A
10000uF
800W/12V; 1600W/24V; 2400W/36V; 3200W/48V
≤
98%
>
99%
-3mv/°C/2V (default)
-35°C to +45°C
IP32
3.6kg
RS232 RS485
≤
3000m
285*205*93mm
5.2 Battery Type Default Parameters
When selecting User, the battery type is to be self-customized, and in this case, the default
system voltage parameters are consistent with those of the sealed lead-acid battery. When
modifying battery charging and discharging parameters, the following rule must be followed:
Over-voltage cut-off voltage>
Charging limit voltage
≥
Equalizing voltage
≥
Boost voltage
≥
Floating charging voltage
>
Boost recovery voltage;
Over-voltage cut-off voltage
>
Over-voltage cut-off recovery voltage;
Low-voltage cut-off recovery voltage
>
Low-voltage cut-off voltage
≥
Discharging limit
voltage;
Under-voltage warning recovery voltage >
Under-voltage warning voltage
≥
Discharging
limit voltage;
Boost recovery voltage >
Low-voltage cut-off recovery voltage
19
20
LI
Battery
——
——
14.4V
——
——
12.6V
11.1V
——
——
——
——
——
——