Update: 2019.SEPT                                                                                                              Page 5 of 6 

 

Maintenance   

Adding Oil   

Attention:     

Keep the tool upright during all operations. 

Connect the air supply, do not press the trigger. 

There might be insufficient oil if you are not able to set the rivet in one hit. Without 

proper lubrication the tool will not work properly and parts will wear prematurely. 

1. Unscrew the oil fill screw from the body using the hex key supplied with the 

tool.(Fig.5)   

 

 

 

 

 

 

 

 

 

 

 

2. Fill the syringe (supplied with the tool) with hydraulic oil. Screw the filled syringe 

in the oil fill screw hole. Inject all of the oil in the syringe into the tool, adequate oil 

has been added if there is oil flowing back to the syringe when you loosen your hand, 

then keep pressing the syringe for two or three times, in order to prevent air go into 

the oil in the tool. (Fig.6)   

 

3. Unscrew and remove the syringe from the body, then screw the oil fill screw into 

the hole using the hex key, wipe off any excess oil. 

 

 

 

 

 

 

 

 

 

 

Fig.5 

Fig.6 

Summary of Contents for SRC-56P

Page 1: ...Update 2019 SEPT Page 1 of 6 SRC 56P Instruction Manual ...

Page 2: ...olved Never connect the tool to any medium other than compressed air Set the air pressure between 5 to 7bar Do not use the tool other than placing break stem rivet The tool must be maintained in a safe working condition at all times and examined at regular intervals for damage and function by trained competent personnel Do not dismantle this tool without prior reference to the maintenance and serv...

Page 3: ...ly Requirement All tools are operated with compressed air at the range of 3 7Kgf cm2 45 105psi We recommended the use of pressure regulators and filtering systems on the main air supply These should be fitted within 3 meters of the tool to ensure maximum tool life and minimum tool maintenance Air supply hoses should have a minimum working pressure rating of 150 of the maximum pressure produced in ...

Page 4: ... during all operations Every 10 000 cycles the jaws jaw housing and upper housing should be cleaned 1 Disconnect the air supply 2 Unscrew nosepiece outer cylinder then jaw housing Fig 1 Fig 2 3 Clean aluminum scraps in outer cylinder jaw housing jaws Fig 3 Fig 4 Fig 2 Fig 1 Fig 3 Fig 4 ...

Page 5: ...y using the hex key supplied with the tool Fig 5 2 Fill the syringe supplied with the tool with hydraulic oil Screw the filled syringe in the oil fill screw hole Inject all of the oil in the syringe into the tool adequate oil has been added if there is oil flowing back to the syringe when you loosen your hand then keep pressing the syringe for two or three times in order to prevent air go into the...

Page 6: ...Update 2019 SEPT Page 6 of 6 ...

Reviews: