Update: 2019.SEPT Page 4 of 6
Maintenance
Cleaning
Attention: Disconnect the air supply during all operations.
Every 10,000 cycles the jaws, jaw housing and upper housing should be cleaned.
1. Disconnect the air supply.
2. Unscrew nosepiece, outer cylinder, then jaw housing. (Fig.1, Fig.2)
3. Clean aluminum scraps in outer cylinder, jaw housing, jaws. (Fig.3, Fig.4)
Fig.2
Fig.1
Fig.3
Fig.4