Battery Compartment Removal (Legacy Power Meters Only)
B a t t e r y C o m p a r t m e n t R e m o v a l ( L e g a c y P o w e r M e t e r s O n l y )
NOTICE
The following section,
Spider Inspection,
should
only
be performed
on a Legacy power meter. Do
NOT
perform the spider inspection
service on an AXS or DZero platform power meter. AXS platform
power meters have a AXS logo next to the battery compartment.
DZero platform power meters include, but are not limited to DZero,
DFour, and XX1 Eagle power meters.
If you remove the battery compartment on an AXS or DZero platform
power meter, you will damage the unit and void the warranty.
Use your fingers to rotate the battery lid counter-clockwise and remove
the lid. Remove the battery and set aside.
⚠
WARNING
Consult the battery manufacturer for safe handling instructions. Keep
the battery out of reach of children. Do not put the battery in your
mouth. If ingested, seek medical attention immediately. Do not use
sharp objects to remove batteries.
NOTICE
Do not use any tool to remove the battery lid. Tools can permanently
damage the power meter making it inoperable. The lid should be
loosened by hand.
Remove the battery compartment screw. Remove the battery
compartment screw assembly and battery compartment, and set them
aside.
NOTICE
Do
NOT
remove the battery compartment on an AXS or DZero
platform power meter, you will damage the unit and void the warranty.
The AXS and DZero platform power meter has a green LED blink on
when awake. Do
not
proceed if a green LED blinks on.
A Legacy power meter has a red LED blink on when the power meter
is awake.
Red LED
Legacy Power Meter
1
2
T10