WARRANTY 

FOUR (4) YEAR LIMITED WARRANTY 

Each

  S

  system  is  manufactured  with  high  quality  components.    SR  Instruments,  Inc. 

warrants  that  all  new  equipment  will  be  free  from  defects  in  material  or  workmanship,  under 
normal  use  and  service,  for  a  period  of  four  (4)  years  from  the  date  of  purchase  by  the  original 
purchaser.    Normal  wear  and  tear,  injury  by  natural  forces,  user  neglect,  and  purposeful 
destruction are not covered by this warranty.  Warranty service must be performed by the factory 
or  an  authorized  repair  station.    Service  provided  on  equipment  returned  to  the  factory  or 
authorized repair station includes labor to replace defective parts.  Goods returned must be shipped 
with transportation and/or broker charges prepaid.  SR Instruments, Inc.’s obligation is limited to 
replacement  of  parts  that  have  been  so  returned  and  are  disclosed  to  SR  Instruments,  Inc.’s 
satisfaction  to  be  defective.    The  provisions  of  this  warranty  clause  are  in  lieu  of  all  other 
warranties,  expressed  or  implied,  and  of  all  other  obligations  or  liabilities  on  SR  Instruments, 
Inc.’s part, and it neither assumes nor authorizes any other person to assume for SR Instruments, 
Inc.  any  other  liabilities  in  connection  with  the  sale  of  said  articles.    In  no  event  shall  SR 
Instruments,  Inc.  be  liable  for  any  subsequent  or  special  damages.    Any  misuse,  improper 
installation, or tampering, shall void this warranty.  

DAMAGED SHIPMENTS 

Title  passes  to  purchaser  upon  delivery  to  Transportation  Company.    Purchaser  should  file  any 
claims for shortage or damage with  the delivery carrier and should refuse any shipment  that has 
obvious external damage.  

RETURN POLICY 

All products being returned to SR Instruments, Inc. require a Return Goods Authorization number 
(RGA).  To receive an RGA, call our Customer Service at 716-693-5977 ext 103 or toll-free in the 
USA and Canada at 800-654-6360 ext 103. 

When  inquiry  is  made,  please  supply  model  and  serial  numbers,  purchase  order  and  reason  for 
return.  

Generally,  deleted,  damaged,  and  outdated  merchandise  will  not  be  accepted  for  credit.    A 
minimum restocking charge of 15% will be assessed on return of current merchandise unless scale 
is returned because of SR error.  

No returns will be accepted after 30 days. 

All  returns  are  to  be  shipped  FREIGHT  PREPAID  to:    SR  Instruments,  Inc.,  600  Young  Street, 
Tonawanda, NY 14150. 

RESTOCKING FEE 

 

15% fee

 will be assessed on return of current merchandise 

 

No fees

 will be charged if the scale is returned because of an error on the part of SR 

Instruments, Inc. 

 

No returns 

accepted after 30 days

.

 

Summary of Contents for SR463iR-3H

Page 1: ...Part No MAN463iR H_201118 Page 1 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S by S Instruments Inc In Floor Platform Scale Operating and Service Manual SR463iR H SERIES ...

Page 2: ...ECKLIST SR463IR 4H SINGLE SHIPMENT 5 ASSEMBLY 6 REPLACEMENT PARTS AND ACCESSORIES 10 SYSTEM DESCRIPTION 10 INTENDED USE 10 CLEANING AND DISINFECTING 11 STORAGE AND TRANSPORTATION 12 SPECIFICATIONS 12 BUTTON FUNCTIONS 13 BASIC SYSTEM OPERATION 14 THEORY OF OPERATION 15 CALIBRATION 16 TROUBLESHOOTING 18 WARRANTY 19 TABLE OF FIGURES Figure 1 Wall Box Assembly Conduit Placement 6 Figure 2 Conduit Plac...

Page 3: ...SSEMBLY 1 ea PIT FRAME ASSEMBLY 1 ea CONDUIT 1 ea LONG FLAT HEAD SCREW 4 ea INSTALLATION INSTRUCTIONS 1 ea 2nd Shipment CABLE ASSEMBLY 1 ea PLATFORM ASSEMBLY 32 IN X 36 IN 1 ea FRONT PANEL ASSEMBLY 1 ea HANDRAIL 1 ea LONG FLAT HEAD SCREW 8 ea LONG BUTTON HEAD SCREW 4 ea STAR WASHERS 4 ea CALIBRATION CERTIFICATE 1 ea WARRANTY CARD 1 ea MANUAL 1 ea DESCRIPTION QUANTITY Box 1 FRONT PANEL WALL BOX ASS...

Page 4: ...ASSEMBLY 1 ea PIT FRAME ASSEMBLY 1 ea CONDUIT 1 ea LONG FLAT HEAD SCREW 4 ea INSTALLATION INSTRUCTIONS 1 ea 2nd Shipment CABLE ASSEMBLY 1 ea PLATFORM ASSEMBLY 32 IN X 50 IN 1 ea FRONT PANEL ASSEMBLY 1 ea HANDRAIL 1 ea LONG FLAT HEAD SCREW 8 ea LONG BUTTON HEAD SCREW 4 ea STAR WASHERS 4 ea CALIBRATION CERTIFICATE 1 ea WARRANTY CARD 1 ea MANUAL 1 ea DESCRIPTION QUANTITY Box 1 FRONT PANEL WALL BOX AS...

Page 5: ...ASSEMBLY 1 ea PIT FRAME ASSEMBLY 1 ea CONDUIT 1 ea LONG FLAT HEAD SCREW 4 ea INSTALLATION INSTRUCTIONS 1 ea 2nd Shipment CABLE ASSEMBLY 1 ea PLATFORM ASSEMBLY 48 IN X 72 IN 1 ea FRONT PANEL ASSEMBLY 1 ea HANDRAIL 1 ea LONG FLAT HEAD SCREW 8 ea LONG BUTTON HEAD SCREW 4 ea STAR WASHERS 4 ea CALIBRATION CERTIFICATE 1 ea WARRANTY CARD 1 ea MANUAL 1 ea DESCRIPTION QUANTITY Box 1 FRONT PANEL WALL BOX AS...

Page 6: ... Area Installation Notes Pit Area Installation Notes This is a rectangular frame so it is important to check the placement specifications to make sure the conduit connection is properly placed facing the wall where the conduit cable connection is located There are holes cut for conduit entry in the center of two sides of the frame so the scale can be placed with either the long or short side again...

Page 7: ...and cable should be left free so cable can be easily connected to the Platform Assembly STEP 7 Figure 5 When the concrete has set remove and discard the installation tabs and screws Install the four long flat head screws into holes left by plate removal Figure 4 Concrete Fill and Installation Tabs Figure 5 Hardware Placement Figure 6 Cable Connection Inside Frame STEP 8 Remove the Platform Assembl...

Page 8: ...Adjustment Bolts so that the Platform Assembly is at an equal distance from all sides of the Pit Frame Assembly Tighten bolts to secure Platform Assembly in place STEP 11 Figure 5 Set the Platform Deck onto the platform base and secure in place with the four 4 top mounting screws Allow 1 8 gap between Platform Assembly and floor STEP 12 Install building ground wire and green ground wire from Displ...

Page 9: ... cont d STEP 15 Install Front Panel Assembly Figure 8 to the previously mounted Wall Box Assembly Use supplied star washers and screws Ensure the screws are securely tightened STEP 16 Restore power to the display STEP 17 Secure the handrail to the platform deck using the eight 8 included flat head screws Figure 8 Front Panel Assembly Figure 9 Handrail Attached to Scale WARNING HAND RAIL IS INTENDE...

Page 10: ...Four 4 identically matched load cell transducers are strategically placed to ensure an accurate representation of the patient s weight regardless of weight distribution The SR463iR H Series display units use 120v AC line power that is mounted in a recessed wall box so the display is flush with the wall Figure 8 The patient s weight is displayed on a 16 character dot matrix liquid crystal display T...

Page 11: ...e a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disinfectants Disinfectant solutions with 1 sodium hypochlorite or 70 isopropyl alcohol are suitable for display user interface and other scale contact surfaces After disinfecting use a soft cloth dampened with ...

Page 12: ... in 81 cm x 91cm SR463iR 3H 32 in x 50 in 81 cm x 127 cm SR463iR 4H 48 in x 72 in 122 cm x 183 cm DISPLAY TYPE 16 Character dot matrix LCD DISPLAY RESOLUTION 0 1 lb 0 1 kg ACCURACY 0 1 1 digit of displayed resolution for calibrated range ZERO One button Auto Tare AUTO POWER DOWN Adjustable between 30 and 300 seconds AVERAGING Automatic digital filter POWER SUPPLY 120v AC 50 60 Hz CALIBRATION Calib...

Page 13: ...on operational on this model RECALL Press to recall the last stored weight The stored weight will be erased when the scale is zero or another stable weight is stored BMI Press to calculate BMI When the BMI is pressed the default value HT 65 in or HT 165 cm is displayed If there is no stored stable weight the display will indicate NO WEIGHT DATA and then go back to the weigh screen WT 0 0 Lb MENU P...

Page 14: ...time or to change the value of a selected digit when setting time and date BASIC SYSTEM OPERATION SETTING SYSTEM ZERO Make sure the scale is free and clear of any obstructions Press and hold the ZERO WEIGH button The displayed message will indicate HOLD TO ZERO and count down to zero Release the button when display message indicates HANDS OFF Make sure that nothing is in contact with the scale whi...

Page 15: ...digitized by the analog to digital converter The converter integrates the analog signal onto the integrating capacitor over a short interval The integrating capacitor is then discharged at a rate proportional to the reference voltage applied to the converter The residual voltage on the integrating capacitor is then multiplied by a factor and again discharged at a rate proportional to the reference...

Page 16: ...USE barbells or un calibrated weights STEP 2 Zero the scale by pressing and holding the ZERO WEIGH button STEP 3 Place the calibrated weight on the scale Wait for scale to stabilize note scale reading STEP 4 Scale readings should be within Calibration Tolerance Table Figure 11 Figure 11 Calibration Tolerance Table Figure 12 Calibration Switch Diagram IMPORTANT CALIBRATION Qualified service personn...

Page 17: ...ange digit Press ENTER to save changes Press WEIGH button to abort any changes STEP 4 Press the MENU button until 500 0Lb HALF is displayed NOTE The Half Scale value is a value between zero and the Full Scale values It is usually close to half the Full Scale value Set the HALF value to the actual quantity of calibrated weight being used for Half Scale Use the UP arrow button to select the digit an...

Page 18: ...ers only appear on half of the display Press the WEIGH button Display shows no reading at all Check to ensure that circuit breaker to the scale is on Display reads WEIGHT OVERLOAD Disconnect the transducer cable from the platform If the WEIGHT OVERLOAD message goes away the problem is in the platform Check to make sure the platform transducer wires are intact and pit is clean and dry For additiona...

Page 19: ...r obligations or liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Instruments Inc be liable for any subsequent or special damages Any misuse improper installation or tampering shall void this warranty DAMAGED SHIPMENTS Title passes ...

Page 20: ... Service Manual Part No MAN463iR H_201118 Page 20 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S S Instruments Inc Precision Technology in Perfect Balance ...