background image

Manual |  Aura Panel gold matrix & dream color

1. SAFETY INSTRUCTIONS

Please read these instructions carefully 

they include the important information 

about the installation usage and 

maintenance of this products 

   

   

•  Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that 

they also receive this instruction booklet.

•  Unpack and check carefully there is no transportation damage before using the fixture.
•  It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
•  Disconnect main power before servicing and maintenance.
•  The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. 

Be sure that no ventilation slots are blocked.

•  Maximum ambient temperature is Ta : 40℃. Don’t operate it where the temperature is higher than this.
•  Unit surface temperature may reach up to 85℃. Don’t touch the housing bare-hand during its operation. 

Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving.

•  In the event of serious operating problem, stop using the fixture immediately. Never try to repair the 

fixture by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please 
contact the nearest authorized technical assistance center. Always use the same type spare parts.

•  Do not connect the device to any dimmer pack.
•  Do not touch any wire during operation and there might be a hazard of electric shock.
•  To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
•  The housing must be replaced if they are visibly damaged.
•  Do not look directly at the LED light beam while the fixture is on.
•  There are no user serviceable parts inside the fixture. Do not open the housing or attempt any repairs by 

yourself. In the unlikely event your fixture may require service, please contact your nearest dealer.

•  Due to the magnifying type lens, please keep the lens out of contact with direct sunlight. Direct sunlight 

can cause heat to build up inside of the unit, which will seriously damage unit.

   

If   using   a   230Vac   50Hz   power   supply,   do   not   connect   in   

series   more   than   8   units,   use   another   mains   supply   for   the   

next   8   units.   

If   using   a   120Vac   60Hz   power   supply,   do   not   connect   in   

series   more   than   4   units,   use   another   mains   supply   for   next   

4   units.   

   

Summary of Contents for Aura Panel gold matrix & dream color

Page 1: ...SquareLED Aura Panel gold matrix dream color...

Page 2: ...ating problem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest author...

Page 3: ...Weight 8 5 kgs 3 Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure t...

Page 4: ...Manual Aura Panel gold matrix dream color 3 1 Fixture Jointing Finished fixture jointing is showed as follows...

Page 5: ...the programming functions MASTER To go backward in the selected functions SLAVE To go forward in the selected functions SOUND To confirm the selected functions 4 DMX input For DMX512 link use 3 5 pin...

Page 6: ...it will automatically return to the main functions without any change after idling 60 seconds Back to the functions without any change press MENU button The main functions are shown below DMX Address...

Page 7: ...display Use the DOWN and UP button to select the 1 1 or 1 2 or 2 2 mode Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU b...

Page 8: ...ected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minu te to exit the men...

Page 9: ...unit will be ready to receive DMX signal or run the built in programs 5 1 Master Slave Built In Preprogrammed Function By linking the units in master slave connection the first unit will control the o...

Page 10: ...6 DMX512 Configuration 4 CH Mode CH1 Warm white 000 107 Blackout 108 255 Show 1 Show 8 CH2 Red 000 255 0 100 CH3 Green 000 255 0 100 Ch4 Blue 000 255 0 100 7 CH Mode CH1 Mode 000 007 Blackout 008 067...

Page 11: ...55 0 100 13 CH Mode CH1 warm white LED 1 6 000 255 0 100 CH2 warm white LED 7 12 000 255 0 100 CH3 warm white LED 13 18 000 255 0 100 CH4 warm white LED 19 24 000 255 0 100 CH5 warm white LED 25 30 00...

Page 12: ...CH1 CH36 Warm white 000 255 0 100 CH37 Red 000 255 0 100 CH38 Green 000 255 0 100 CH39 Blue 000 255 0 100 CH40 Red 000 255 0 100 CH41 Green 000 255 0 100 CH42 Blue 000 255 0 100 CH43 Red 000 255 0 100...

Page 13: ...ct 2 2 Number 001 015 No function 016 215 Number 0 Number 9 216 255 To count forwards 0 up to 9 from slow to fast 2 3 letter 000 021 No function 022 255 Letter A Letter Z CH39 Dimmer 000 255 0 100 CH4...

Page 14: ...Manual Aura Panel gold matrix dream color 2 2 mode connection...

Page 15: ...ular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used 8 Troubleshooting Following are a f...

Page 16: ...ive IC on the PCB might be out of condition 9 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which...

Page 17: ...l Aura Panel gold matrix dream color Das LichttechnikhausVertriebs GmbH Rudolf Diesel Str 3 D 89312 G nzburg Telefon 49 0 82 21 207 98 0 Fax 49 0 82 21 207 98 69 E Mail info lth gmbh de Web www lth gm...