13
GENERATOR RUN LIMITS
This page will enable you to set the parameters for RUN TIME
for the air conditioner settings. Once the air conditioner
has brought the coach down to the chosen temperature
and cycled off, the generator should continue to run for ten
minutes.
It will also allow you to set the MAXIMUM run time for the
generator.
Use the + and – buttons to adjust the settings.
Select the NEXT button to continue.
QUIET TIME SETTINGS
Select the box in the top right hand corner to enable or
disable QUIET TIME settings. QUIET TIME settings allow you
to determine when the generator will not be allowed to run.
Select the box above the FINISH button to enable or disable
a battery top up just before the system goes into QUIET TIME
settings.
Select the FINISH button to complete EASY SETUP.
AGS MANUAL SETUP
Select MANUAL SETUP for more in depth set up choice and
will allow you to set all parameters for the the AGS system.
You can choose BATTERY or HVAC system to trigger the AGS.
You can choose your RUN TIMES, QUIET TIMES and BATTERY
CAPACITY for shut down parameters.
Touch FINISH when complete to return to the POWER
MANAGEMENT main page. Touch AGS to enable the AGS
system. Hold continue for 5 seconds to trigger the AGS
system.
NOTE:
If both the LOW BATTERY VOLTAGE and the HVAC
LOADS are activated, which ever one needs the most run
time to acquire the desired result will override the other
setting.
NOTE:
When AGS is used for the HVAC system (air
conditioning), the appliance must be selected on the HOME
page, the temperature must be selected and set on the
HOME page, and the fan on the HOME page should be set
to FAN AUTO.