background image

14

p i c l t d .c o m

Pipeline Inspection Company, hereafter referred to as (SPY

®

) warrants that 

SPY

®

 Model PJM Pocket JeepMeter shall, under normal use and service, 

be free from defects in material and workmanship. SPY

®

‘s entire warranty 

obligation shall be limited to, at SPY

®

’s option, the repair or replacement free 

of charge to the buyer of any defective equipment or parts thereof which 

prove to be defective in material and workmanship under normal use and 
service.

Claims for defective parts must be made in writing within three (3) months 
after shipment of the equipment from the works of SPY

®

. Fast wearing and 

consumable parts including, but not limited to, electrodes and ground cables, 
are expressly excluded from the warranty. SPY

®

 shall have the option to 

require return of a claimed defective part to SPY

®

’s manufacturing facility in 

the U.S.A., freight prepaid by buyer for examination to establish buyer’s claim.

Except with SPY

®

’s prior written approval, SPY

®

 shall not be liable (a) for 

the cost of repairs, alterations or replacements or any expense connected 
therewith made or incurred by the buyer or its designers, or (b) for defects 
resulting from alterations or repairs made by others than SPY

®

 or its 

approved representatives.

SPY

®

 shall not be liable for damages, including but not limited to direct, special, 

indirect or consequential, resulting from the handling, or use, whether alone 

or in combination with other products, or any SPY

®

 equipment or third party 

designed or manufactured equipment, including without limitation, any loss 
or damage sustained or caused by the operation and use of the equipment 
which is improperly operated or its successful operation is impaired by 
natural elements after its delivery to the buyer.

The foregoing warranty is exclusive and in lieu of all other warranties 

whether written, oral or implied (including without limitation, any warranty 
of merchantability or fitness for purpose).

warrant y

Summary of Contents for PJM Pocket JeepMeter

Page 1: ...PIPELINE INSPECTION COMPANY picltd com Spy pocket Jeepmeter operating instructions...

Page 2: ...work which supplies buildings used for domestic purpose is a registered trademark of Pipeline Inspection Company Houston Texas 77055 United States A copy of this Operating Instructions Manual can be d...

Page 3: ...ibration 4 Principles of Operation 5 Pocket JeepMeter Overview 6 Battery Instructions 8 User Safety 9 Pocket JeepMeter Operation 10 Troubleshooting Guide 12 Technical Specifications 12 Maintenance Rep...

Page 4: ...eavy usage Recalibration of our equipment should be performed ONLY at a SPY Authorized Service Center due to the unique calibration process test equipment utilized and properly trained SPY technicians...

Page 5: ...e form of holiday detectors typically has this type of shape and therefore prevents the use of conventional RMS voltmeters The SPY Model PJM enables the operator to measure pulse up to 20 kV The SPY 7...

Page 6: ...ut voltage of Pulse Only Holiday Detectors such as our model 785 790 Portable Holiday Detectors or our 125 135 In Plant Holiday Detectors The SPY Model PJM Pocket JeepMeter provides the ultimate in co...

Page 7: ...oltage Analog Display 2 Power Battery Indicator Light 3 Ground Input Terminal 4 High Voltage Pulse Input Terminal 5 On Off Bat Switch 6 Quick Change 9 Volt Battery Compartment 7 Ground Cable 8 High Vo...

Page 8: ...the notch on the bottom of the battery compartment lift up and pull out to slide the battery tray out STEP 3 Insert a new 9 volt battery into the battery tray and push the battery tray firmly back in...

Page 9: ...ltage The operator may be subject to electrical shock if the meter is not properly grounded and or operated in accordance with the instructions and procedures described within these operating instruct...

Page 10: ...lead to electrode or metal electrode wand connector on the holiday detector STEP 4 Connect ground black test lead to ground black input jack on base of meter STEP 5 The preferred method of grounding i...

Page 11: ...back in its case NOTE The meter ground may be connected to the detector ground for measuring detector output voltage only This does not take into consideration ground path losses STEP 6 After double...

Page 12: ...the unit with a new battery technical specifications MODEL POCKET JEEPMETER Measurement Type Pulse Voltage Range 1 20 kV Measurement Accuracy 5 75 deg F Display Type Analog Battery 9 Volt Battery Unit...

Page 13: ...opened by anyone other than a SPY Authorized Service Center or SPY manufacturing facility In the event the unit fails to operate properly please return your unit to a SPY Authorized Service Center or...

Page 14: ...yer for examination to establish buyer s claim Except with SPY s prior written approval SPY shall not be liable a for the cost of repairs alterations or replacements or any expense connected therewith...

Page 15: ...td com 15 related equipment SPY MODEL JM JEEPMETER SPY MODEL DCPJM DC POCKET JEEPMETER Please call our office at 713 681 5837 or email us at sales picltd com for more product details or to place an or...

Page 16: ...PIPELINE INSPECTION COMPANY picltd com...