TO START OPERATIONS – THIS METER REQUIRES NO
BATTERIES. IT OBTAINS ITS ENERGY FROM THE VOLTAGE
OF THE HOLIDAY DETECTOR BEING MEASURED.
STEP 1:
With the holiday detector turned OFF, connect the high
voltage cable (red cable) to the red high voltage DC input terminal
on top of the DCPJM and then connect the other end of the high
voltage cable (alligator clip) to the voltage output or electrode of the
holiday detector.
STEP 2:
Connect the ground cable (black cable) to the black ground
input terminal on bottom of the DCPJM and then attach the other end
(alligator clip) to the bare metal of the pipe. This takes into account
all ground path losses which may vary due to soil and moisture
conditions and measures actual working voltage of the detector.
NOTE:
The DCPJM ground may be connected to the detector
ground for measuring detector output voltage only. This does not
take into consideration ground path loss.
CAUTION!
This meter is used to measure low energy high
voltage. Operator may be subject to electrical shock if meter
is not properly grounded and / or operated in accordance with the
instructions and procedures prescribed below.
To start dc p ocke t
Jeepme ter opErAT IoNs