9
95-03012
CHECK AT 4 POINTS AROUND
COUPLING-EVERY 90°
In-line Drives.
For initial pump installation, and for rechecking alignment, the following steps are
advised:
Use a flexible coupling to connect the drive to the pump. Many different types are available, including
couplings with slip or overload provision.
FLUID
COUPLING
SLIP
OVERLOAD
DETENT
FLEXIBLE
MEMBER
GEAR
TYPE
RUBBER
CUSHIONED
A flexible coupling is used to compensate for end play and small differences in alignment. The
pump and drive shaft should be aligned as closely as is possible.
Check angular alignment:
Using feeler gauges, or taper gauges.
Adjust to get equal dimension at all points. At the
same time set space between coupling halves to
manufacturer’s recommended distance.
FEELER OR TAPER GAUGE
SHIM AS
NEEDED
Check parallel misalignment:
Use straight edges and shims:
MOVE DRIVE
AS NEEDED
SHIM HEIGHT AS
NEEDED
After piping is complete, and drive and couplings are aligned, turn pump shaft manually
to see if it turns freely without binding.
Note:
Covers have been removed for illustration purposes only. The pump
cannot be operated with the cover removed.
TOP SHAFT
DRIVE
LOWER SHAFT
DRIVE
LOWER SHAFT
DRIVE
TOP SHAFT
DRIVE
Check rotation direction
of drive to see that pump will rotate in proper direction.
(“Liquid End” of pump is shown below.)
CONNECT COUPLING HALVES AND INSTALL COUPLING GUARD.
Determine rotation direction by looking at the motor coupling.
Figure 1
Summary of Contents for Universal 5000 Industrial Series
Page 6: ...4 95 03012 SECTION II INSTALLATION...
Page 42: ...40 95 03012 5050 UNIVERSAL INDUSTRIAL PUMP 5050 2 17 99...
Page 44: ...42 95 03012 5060 UNIVERSAL INDUSTRIAL PUMP 5060 2 17 99...
Page 46: ...44 95 03012 5070 UNIVERSAL INDUSTRIAL PUMP 5070 2 17 99...
Page 48: ...46 95 03012 5080 UNIVERSAL INDUSTRIAL PUMP 5080 2 17 99...
Page 55: ...95 03012 53...
Page 57: ......