8. CU Assembly and Startup
8.2.
Single seat valve
Caution!
The permanent magnet is made of fragile material
and must be protected against mechanical load . –
Risk of fracture!
The magnetic fields can damage or delete data
carrier or influence electronic and mechanic
components.
Assembly of the control unit on the valve
1.
Assembly of the adapter on the single seat valve. Fasten with
4 screws.
2.
Secure switching cam with Loctite semi-solid and fasten it.
3.
Place the control unit via the switching cam onto the adapter.
Observe alignment!
4.
Attach the clamp rings and fasten them with the screws.
switching cam with
permanent magnet
CU cover
CU base with
electronic module,
sensor tower and
solenoid valves
clamp ring
fastening screws
adapter
actuator
!