RD5100H
2
O+ Operation Manual
32
© 2018 Radiodetection Ltd
becoming too hot to touch, resulting in risk of personal
injury and damage to the equipment.
The FlexiTrace can be used in two modes: Sonde mode
or Line mode. In sonde mode only the tip of the
FlexiTrace is energized whilst in line mode its whole
length is energized.
To use as a sonde, connect both transmitter leads to the
FlexiTrace stud terminals. As the FlexiTrace terminals
are not color coded it does not matter to which terminals
the leads are connected. To use the FlexiTrace in line
mode, connect the red transmitter lead to one of the
FlexiTrace terminals and connect the black transmitter
lead to a suitable ground connection.
Figure 8.7 - FlexiTrace