21
6.5.8 Test Mode
1. Test Mode is active when the user exits Program
Mode after selecting operation in MANUAL CY-
CLE.
2. Test Mode is comprised of ten (12) screens (screen
descriptions follow the table below on the next page).
Each screen corresponds to one of ten program
steps (described in the table below).
3. Press to advance from one screen (test step) to
the next.
IMPORTANT:
Be sure to read and understand all
cautions listed with the screen (program step) de-
scriptions.
4. Upon entering Test Mode, the program can be at any
one of the twelve steps.
5. To exit Test Mode:
a. Press and hold
for 3 seconds to exit Test
Mode. The display switches to Screen 2 of Setup
Mode.
b. Use
to select ENERGY MANAGEMENT,
DEWPOINT CONTROL or FIXED CYCLE.
c. Press and hold
for 3 seconds to exit Setup
Mode and activate Display Mode.
d. Dryer operation continues from the last step active
when exiting the Test Mode.
Program Step
1
2
3
4
5
6
7
8
9
10
11
12
LT status
Drying
Drying
Drying
Drying
Drying
Drying
Off
Depress
Heat
Cool
Down
Sweep
Repress
RT status
Off
Depress
Heat
Cool
Down
Sweep
Repress
Drying
Drying
Drying
Drying
Drying
Drying
1PS
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
then Open
Open
Open
Open
Open then
Closed
2PS
Closed
Closed
then Open
Open
Open
Open
Open then
Closed
Closed
Closed
Closed
Closed
Closed
Closed
LT drying solenoid (B)
On
On
On
On
On
On
Off
Off
Off
Off
Off
Off
LT depress solenoid (F)
Off
Off
Off
Off
Off
Off
Off
On
On
On
On
Off
LT purge solenoid (C)
Off
Off
Off
Off
Off
Off
Off
Off
On
On
On
Off
RT drying solenoid (A)
Off
Off
Off
Off
Off
Off
On
On
On
On
On
On
RT depress solenoid (G)
Off
On
On
On
On
Off
Off
Off
Off
Off
Off
Off
RT purge solenoid (D)
Off
Off
On
On
On
Off
Off
Off
Off
Off
Off
Off
LT inlet valve (V1)
Open
Open
Open
Open
Open
Open
Closed
Closed
Closed
Closed
Closed
Closed
LT depress valve (V9)
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Open
Open
Open
Open
Closed
LT purge valve (V3)
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Open
Open
Open
Closed
RT inlet valve (V2)
Closed
Closed
Closed
Closed
Closed
Closed
Open
Open
Open
Open
Open
Open
RT depress valve (V10)
Closed
Open
Open
Open
Open
Closed
Closed
Closed
Closed
Closed
Closed
Closed
RT purge valve (V4)
Closed
Open
Open
Open
Open
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Purge Saver Valve
Closed
Closed
Open
Closed
Closed
Closed
Closed
Closed
Open
Closed
Closed
Closed
Purge Inlet valve
Closed
Closed
Open
Open
Open
Open
Closed
Closed
Open
Open
Open
Open
Temp display - location
Left
Right
Right
Right
Right
Right
Right
Left
Left
Left
Left
Left
Table 2
Cycle Sequence Steps