© SPX FLOW, Inc.
Form No. 1000623
Rev. 6 Jan. 10, 2017
Initial Setup continued
• Do not strike, misuse or abuse any of the equipment. If any abuse or misuse of the equipment is
evident, the warranty shall be invalid and the Manufacturer shall not be responsible for any injuries
or failures as a result.
• If not in use, and when practical, disconnect the wrench and pump from the power supply to prevent
accidental starting.
Preparing the Torque Wrench for Use
IMPORTANT: For a copy of the calibration certificate for a specific hydraulic torque wrench,
e-mail [email protected] with serial number of the hydraulic torque wrench.
CAUTION: For top performance, frequently inspect wrench, pump, and accessories for visual
damage. Always follow instructions for proper wrench and pump maintenance. Do not use other
equipment to increase the capability (i.e., hammering on socket wrench).
Changing the Drive Direction
To change the drive direction:
1. Press and hold the drive-release button and pull out the square drive. The square drive, retainer cap,
and button assembly are now free.
2. To reinstall, insert the square drive into the opposite side of the tool head, aligning the splines, and
replace the retainer cap assembly.
3. Pull the square drive to verify that it is locked in position.
1
2
Item
Description
1
Square Drive Release Button
2
Square Drive Cap
Figure 2. Square Drive Operation
Setting Torque
1. Verify the system is fully connected and the proper power supply is available.
2. Refer to the Pressure/Torque Conversion Chart in the Performance Specifications section. Note that
this pressure is set on the pump.
3. Turn on the pump.
4. Press and hold the remote control button.