Maintenance
Waukesha Cherry-Burrell
®
Brand Universal 3 Pump
Page 44
95-03103
02/2021
Double Mechanical Seal
Remove Flush-Side Seal Components
NOTE:
For single mechanical seal, see page 37. For O-ring
seals, see page 68.
1. Remove the flush-side rotary seal from each shaft. Use
caution not to damage the seals during removal.
2. Remove the flush-side rotary seal O-ring from each shaft.
3. Remove the adjusting ring from each pump shaft.
Figure 69 - Remove flush-side rotary
seal
Figure 70 - Remove O-ring
Figure 71 - Remove adjusting ring