Waukesha Cherry-Burrell
®
Brand Universal 3 Pump
Maintenance
02/2021
95-03103
Page 39
134-U3 and smaller pumps: Install Seal
Components (single mechanical seal)
NOTE:
SPX FLOW recommends
replacing elastomers every time the
pump is serviced.
NOTE:
For single mechanical seal on 180-U3 and larger pumps,
see page 42. For double mechanical seal, see page 44.
1. Lay out the required parts for each seal (040-U3 shown).
CAUTION
To lift the body of a 130, 134, 180, 184, 210, 214, 220, 224, 320,
or 324-U3, use a lifting strap threaded through the ports on either
side of the body.
2. Install the shaft ring with the notch openings facing toward
you as shown in Figure 54.
NOTE:
Make sure the notch openings in the shaft ring are
perpendicular to the ports, and in line with the bores. See
Figure 60 on page 41.
3. Figure 55 shows the shaft ring installed.
Figure 53 - Single Mechanical Seal
(040-U3 shown)
Figure 54 - Install shaft ring
Figure 55 - Ring installed