The alarm will sound:
• Between 60 and 90 minutes when exposed to 50ppm
of CO
• Between 10 and 40 minutes when exposed to 100ppm
of CO
• Within 3 minutes when exposed to CO levels of
300ppm or more
WARNING:
Apparatus conforming to this standard may
not protect people who are at special risk from carbon
monoxide exposure by reason of age, pregnancy or
medical condition If in doubt, consult your doctor
A carbon monoxide detector is not a substitute for a
smoke alarm or a combustible gas detector
Replace unit after 7 years of operation
DISPOSAL
Waste electrical products should not be disposed of with regular
household waste Please recycle where facilities exist Check with your
local authority, retailer or manufacturer for recycling/disposal advice as
regional variations apply
The power pack should be deactivated before disposal To do this, insert
the pins on the end of the disabling tab back in to the socket on the
underside of the detector If the disabling tab is no longer available then
the clip can be replicated by opening out a thin metal paper clip into a
U-shape
WARNING:
DO NOT ATTEMPT TO OPEN - DO NOT BURN