background image

Model 340XRi / 680XRi / 1220XRi DC drive product manual HG102909 iss 9 

 

 

The product is enclosed in a stylish DIN rail mounted enclosure 
with plug in screw terminal connections. 

 

 

 

 

 

   

 

Height Width Depth 

340XRi 105  60  120 
680XRi 105  70  120 
1220XRi 105  70 

120 

For Forward / Reverse operation  
Move the wire from T1 into T4. 
Connect T1 to T6. The pushbutton 
inputs T7/8 can then be used for 
direction control.

 

 

Earthing 

A clean signal earth connection should be made to terminal 10 (Common). The motor

 

earth should be connected to the 

earth in the system enclosure.

 

 

This is available at 

 

www.sprint-electric.com

 ‘Downloads’, ‘Technical Data’. 

If the unit is to be used in the domestic environment, then for installations in the EU a supply filter 
is recommended in order to comply with EN6800-3. Sprint Electric part number FRLN16. For EU 
EMC compliance guidelines refer to the above website. 
 

Health and safety at work. Electrical devices constitute a 
safety hazard. It is the responsibility of 

the user to ensure compliance with any acts or bylaws in force. Only skilled persons should install 
this equipment. Sprint Electric Ltd. does not accept any liability whatsoever for the installation, 
fitness for purpose or application of its products. It is the users responsibility to ensure the unit is 
correctly used and installed. 

 

 
 

 

 

 

MECHANICAL DETAILS

 

Supply 

Select 

Sw1        AVF 
Sw2   Spd x 2

 

Max Speed

Min Speed

Up Ramp

Stability

Max Current 

Comparator 

Level preset

Lift up cover 

Terminals

12 to 21 

  A+  A-    F-   F+   N    L

Fan exhaust

For models 

680 / 1220XRi

DIN rail 

release catch 

with bottom 

rear access 

slot. (Unplug 

terminals to 
gain access) 

APPLICATIONS GUIDE

 

WARNINGS

 

Sprint Electric Limited, Arundel, UK
Tel.   

+44 (0)1903 730000

Fax.   

+44 (0)1903 730893

Email. [email protected] 

www.sprint-electric.com

 

IR Comp

Alarm lamp

Stall lamp 

Increasing brightness 
for imminent trip. 

Power ON lamp  

Brighter for positive current.

 

Down Ramp

Terminals

1 to 11 

Armature

Field

Basic single direction speed control with tach feedback

  1       2   3    5   9          10  11    A+   A-     F-   F+

10K Pot

RUN

Tach 

Earth

Reviews: