17
Options
Max spd
Min sp
d
Ram
p
Ram
p
Stab
ON
1 2
Stall
Avf/T
ach
Spd
x 2
Alarm
Level
: relay driver threshold. +/-(0.5% to 105%). (+/-10.5V).
Symmetrical about zero.
Increasing brightness indicates imminent trip.
Ramp up
: rotate clockwise for a faster response. 20 to 1 seconds up ramp
rate. For +100% speed change.
Minimum speed
: rotate clockwise to increase minimum speed.
*
5K potentiometer provides 0 to 30% of maximum speed.
“Fan failure” alarm is active when lit.
Refer to text.
Maximum speed
: rotate clockwise to increase speed, 40 V to 200 V
(armature or tach feedback V
olts).
LV60 model has
Avf range 10 V to 50 V
.
ON
1 2
Avf/T
ach
Spd
x 2
ANTI-CLOCKWISE
MID-W
AY
CLOCKWISE
*
Assumes using a 10K
speed reference potentiometer
I max
IR comp
Power
Power is present when lit.
The LED is brighter for positive current.
IR compensation
: rotate clockwise to increase level of armature voltage
droop compensation. 0 to 25%. Excessive rotation may cause instability
.
Always set fully anti-clockwise in
Tacho mode.
Level
Ramp down
: rotate clockwise for a faster response. 20 to 1 seconds
down ramp rate. For -100% speed change.
Maximum current
: rotate clockwise to increase current limit.
0 to 100% current limit.
Stability
: gain 1 to 10.
DANGER!
ELECTRIC
SHOCK HAZARD
MOT
OR
ARMA
TURE
MOT
OR
FIELD
AC
SUPPL
Y
A+
A-
F-
F+
N
L
2-pole
AC supply switch or contactor
semi-
conductor
fuse
For armatures
with a time constant of
less than 5 ms,a DC choke
must be wired in series
SUPPL
Y SELECT
11
0
240
10K
1
+10
2
MIN
3
IP
4
COM
5
IP+/-
6
PB+
7
8
9
10
12
13
14
15
16
17
18
19
20
21
Acw
Cw
ST
ART or
RAMP
TO ST
OP
switch
OP+/-
PB-
RUN
COM
11
Tach
RLOP
RLIP
OVLD
ROP
DEM
SOP
RUN switch
Close to COMMON
Open for coast to ST
OP
TRIP
IOP
SPD
TRQ
Optional T
ACH
for
speed feedback
Optional
current ind7.5 V = 150%
Optional
speed ind5 V = 100%
DANGER!
ELECTRIC
SHOCK HAZARD
Earth
W
iring for ON OFF switch with ramp or coast to stop
10K
1
+10
2
MIN
3
IP
4
COM
5
IP+/-
6
PB+
7
8
9
10
Acw
Cw
ST
ART or
RAMP
TO ST
OP
switch
OP+/-
PB-
RUN
COM
11
Tach
RUN switch
Close to COMMON
Open for coast to ST
OP
Optional T
ACH
for
speed feedback
DANGER!
ELECTRIC
SHOCK HAZARD
Earth
Basic single direction speed control with tach feedback
USER ADJUSTMENTS
COM
5
PB+
7
8
PB-
IP+/-
6
+/-0 to 10.5 V
4
OP+/-
closed
closed
closed
open
open
closed
open
open
Terminal 7
Terminal 8
*
INVER
T
NON-INVER
T
INVER
T
Mode
No ef
fect on selected mode
Powers-up in INVER
T
*
+/-0 to 10.5 V
CAUTION!
EQUIPMENT DAMAGE HAZARD
Do not disconnect the supply while the drive is running. For drives supplied via an
AC supply contactor, either open the T9 RUN input, or ensure that motor shaft is
stationary and is not under load, before opening the contactor.
When using a mains supply contactor, we always recommend to connect a
Normally Open auxiliary contact of the contactor in series with T9 RUN input.
•
Alternative wiring option
The wiring diagram below shows the addition of speed and
current indicators on Terminal 18 and Terminal 19 respectively.