background image

5/12

EN

INSTALLATION INSTRUCTIONS

Introduction

Thank you for buying this 

SpringCard FunkyGate

 

Reader for your access control system. 

SpringCard 

FunkyGate

 is a wall-mount reader. In order to install 

it easily and correctly please follow the instructions 
contained in this guide.

Product listing

This Installation Instruction guide targets the 

following products :

Order #

Product

SC16092

FunkyGate-IP PC/SC

: new generation 

wall-mount RFID/NFC/contactless card
Reader, with Ethernet interface (10 or 

100 Mbit/s)

Precautions for installation & use

The  

SpringCard  FunkyGate   IP   PC/SC  Coupler

communicates   with   contactless   cards,   tags   or   any
other objects by the mean of RFID/NFC technology in

13.56MHz   range.   RFID/NFC   works   thanks   to  short
distance radio waves that propagates on a straight-

line (magnetic field).

These  radio waves  can't  travel through  metal.  The

coupler’s operations may also be disturbed because
of other active devices in the nearby. Please respect

the following rules when installing your  

SpringCard

FunkyGate IP PC/SC Coupler.

The antenna shall not be installed in the
vicinity of any other RFID or NFC reader,

even   from   another   manufacturer   or
technology.   The   distance   between   two

readers shall be at least 30cm,

It is highly disadvised to place any metallic
or conductive area in front of the antenna

because it could distort the operation of
your antenna,

Keep away from any electronic equipment
that is likely to disturb the communication

at 13.56MHz,

Do not install your 

SpringCard FunkyGate

 Reader:

In the vicinity of another access control reader, 

even from another brand or another technology. The 
distance between two readers in the 13.56MHz range

shall be 30cm or more ;

On a metal plate, or near any kind of metal area 

(aluminium door or window frame, thermal 
insulation screen etc). There must be at least 8cm 

between the Reader's back and any metal plate, and 
there must be at least 12cm between the Reader's 

sides and any object containing metal in the nearby ;

Near another electronic equipment, because the 

waves it emits for operation, or even its internal 
shielding, may alter the performances of your 

SpringCard FunkyGate

 Reader.

Wiring, configuration and test

Once your 

SpringCard FunkyGate

 Reader is installed, 

the next step is to connect it to your access control 

system, and to load the correct configuration 
depending on: 

The kind of cards/tags you'll be using ;

The output format your controllers are waiting 

for.

The rest of the document is a configuration tutorial 
for the first use of your reader.

Contacting Support

Thank you for using the online form at address 

www.springcard.com/support

 for any question or technical 

support request. 

PMU18296-AA 

Summary of Contents for FunkyGate-IP PC/SC

Page 1: ...FunkyGate IP PC SC QuickStart Guide EN Guide de d marrage rapide FR...

Page 2: ...mm Tol rance g n rale 0 1mm EN DRILL TEMPLATE All dimensions are in mm General tolerance 0 1mm Small holes drill diameter 3mm Large holes drill diameter 4mm FR PLAN DE PER AGE Toutes les dimensions so...

Page 3: ...3 12 PMU18296 AA...

Page 4: ...s utiliser 4 Must be OFF Position obligatoire Do not use Ne pas utiliser EN Table 1 shows the power supply needed for the operation of your reader Table 2 shows you details regarding the 4 switches Th...

Page 5: ...isadvised to place any metallic or conductive area in front of the antenna because it could distort the operation of your antenna Keep away from any electronic equipment that is likely to disturb the...

Page 6: ...e of the reader breathes in blue color after a buzzer bip Don t use a network hub or switch during configuration 4 Launch the application SpringCard NetPCSC Configuration You see your coupler in the l...

Page 7: ...or windows Installation on other operating systems Using your FunkyGate IP PC SC PC SC Coupler under Apple MacOS X Linux or other systems compliant with UNIX is possible thanks to the open source PCSC...

Page 8: ...d com en solutions pcsc sdk html This product s reference manual for developers is available at www springcard com en download find file pmd2271 Need help Most questions are already answered in the FA...

Page 9: ...ctrice devant l antenne car cela pourrait alt rer le bon fonctionnement de l antenne loigner tout quipement lectronique susceptible de perturber la communication 13 56MHz Vous ne devez pas installer v...

Page 10: ...t lorsque le symbole au milieu du lecteur respire de couleur bleue apr s un bip de buzzer Il est recommand de relier directement le coupleur l ordinateur ne pas passer par un hub switch r seau pour la...

Page 11: ...eur Pour plus de d tails se r f rer la page tech springcard com 2016 springcard netpcsc for windows Mise en route autres syst mes d exploitation L utilisation de votre FunkyGate IP PC SC avec le syst...

Page 12: ...namiquement Il appartient donc au fabricant de l quipement final dans lequel ce composant sera utilis de s assurer du respect des normes standards et r glementations y l obtention des marques CE et FC...

Reviews: