The AutoJet
®
ES250 Electrostatic Spray Control Panel supplies the required voltage to the electrostatic nozzles via a
30,000 VDC (30 kVDC) negative polarity HVPS. At the control panel, the operator can adjust the applied voltage, pump
frequency and start or stop the system modes.
GASKET
The control panel has a gasket installed which creates a seal between the door and the body of the unit. Exercise
caution when opening the unit door as to not damage the gasket. Debris inside the control panel may cause damage to
the system.
4.1 MOUNTING THE PANEL AND DOOR DIAGRAM
MOUNTING
When selecting a control panel mounting location, consider the high voltage cable routing required and your
purchased cable length in relation to the nozzle mounting location. Make sure the control panel is mounted within an
acceptable distance to the nozzle, it is easily accessible to system operators, and the grounding lug is connected to a
grounded GFCI outlet (Figure 4.1).
If mounting the panel to the wall, in a location that is close to your nozzles install wall anchors that are designed to
support at least 25 lbs. (11.34 kg) according to the anchor manufacturer
’
s specifications. The mounting holes are on
6” (152
mm) centers and are made for
1/4” (6
mm) screws with
3/8” (10
mm) diameter screw heads (Figure 4.1
-
1).
Figure 4.1
-
2: Labeled control panel door diagram
Figure 4.1
-
1: Dimensions and mounting hole pattern
SPRAY CONTROL PANEL DOOR LABELED DIAGRAM
The control panel door uses illuminating pushbuttons to relay system information. The POWER switch will illuminate
when system power is on. The RESET and STOP pushbuttons will illuminate related to system operation and fault
status (Figure 4.1
-
2).
Reset Pushbutton: Illuminates when no
fault condition is detected.
Push to reset after correcting a system
fault
Stop Pushbutton:
When pressed, OUTPUT 2
will turn on and pushbutton
will illuminate
Power Switch:
Will illuminate
when the system
is powered on
10.72” (272
mm)
6” (152
mm)
R.
0.13” (3
mm)
Figure 4.1: Grounding lug