4.2 WATLOW CONTROLLER
FRONT PANEL CONTROLS AND INDICATORS
•
Power on pushbutton, illuminated –
when momentarily pressed, applies power to the AccuCoat® MV10 Heated
Spray System.
•
Power on indicator
-
when indicator is on, indicates power is applied to the system.
•
Power off pushbutton
-
when momentarily pressed, turns off power to the AccuCoat MV10 Heated Spray System.
•
Disconnect
-
use to disconnect power from the panel and components.
•
Pump selector switch, illuminated –
when selector switch is on, pump is enabled.
•
Pump on indicator
-
when indicator is on, pump is on.
•
Heater selector switch, illuminated –
when selector switch is on, heater is enabled (pump must be turned on).
•
Heater on indicator
-
when indicator is on, heater is on.
•
Auto
-
Refill selector switch, illuminated –
when selector switch is on, Auto
-
Refill is enabled.
•
Auto
-
Refill on indicator
-
when indicator is on, Auto
-
Refill is filling the tank.
•
Low Level indicator
-
when indicator is on, indicates the level in the tank is below the low level setpoint.
•
Heater controller
-
use to program the heat controller and input the heater set points.
Reference the component manual for further operating instructions.
OPERATING PROCEDURES:
1.
Disconnect turned on
2.
Operator powers system on
3.
Operator opens air vents on the heating loop
4.
Operator fills system with conditioning fluid (water)
5.
Operator turns pump on and purges air in line
6.
Observe the conditioning fluid pressure (20
-
30psi)
7.
Operator sets water temperature with arrows on the heat controller
8.
Turn on heater and observe temperature and adjust to desired temperature if needed
9.
Turn off heater/pump
10.
After use disconnect air and drain tank if needed.
Actual conditioning fluid temperature
Conditioning fluid temperature "Set point"
Push to increase the set point
Push to decrease the set point
EZ
-
Heater fault "Reset"