Electrical Power Connection
o
Connect one end of the electrical power cord to the receptacle on the control panel and connect the other end into a
120/60/1 VAC power source. (US voltage). For International applications be sure that you have the correct power cord.
System is capable of using up to 240v 50/60 Hz Single Phase power.
Air and Liquid Connections
The system comes with push tube bulkhead fittings for making air and liquid connections. The fittings are located on the
right side of the unit. The push tube fittings make connecting the system easy.
The fully configured 1550+ AutoJet modular spray system has the following air and liquid connections:
Air Connections
o
The system is provided with an air filter and lock out valve assembly. The unit is provided loose for you to mount either
directly to the unit or your preferred location.
o
Connect a dry, clean 80-100 psi max air supply line to the input fitting of the lockout valve. Make sure that the lockout
valve and the ball valve on the pump inlet are both in the closed position prior to connecting the unit to the air supply.
o
For systems that control pneumatically actuated nozzles connect 1/4” O.D. tubing from the Cylinder Air out port of the
bulkhead to the spray nozzle(s) cylinder air ports.
o
Tubing may be supplied with optional spray nozzle hook up kit
Note
metric nozzle hook up kits are not available
o
Metric systems use 6 mm O.D. tubing
o
Connect 3/8” O.D. poly tubing from the Atomization Air and Fan Air push-in fittings (if needed) on the side of the
enclosure to their corresponding fittings on the spray nozzle(s).
o
Tubing may be supplied with optional spray nozzle hook up kit
Note
metric nozzle hook up kits are not available
o
Metric systems use 10 mm O.D. tubing
Liquid Connections - Pump version
The 1550+ Pump Version is designed to draw fluid from tote or vessel using the systems pump. It is not designed to receive
pressurized fluid.
Air and liquid connection
locations
Summary of Contents for 1550+ AutoJet
Page 35: ...35 Graphic Representation of Fixed Spray Time Using PWM Variable Spray Time...
Page 74: ...74 Data Sheets Pump Versions...
Page 75: ...75...
Page 76: ...76...
Page 77: ...77 Data Sheets Pump Less Versions...
Page 78: ...78...
Page 79: ...79...
Page 80: ...80 Data Sheets Pressure Pot versions...
Page 81: ...81...
Page 82: ...82...
Page 83: ...83...
Page 84: ...84 Control Panel Only Version...
Page 85: ...85 Notes...