ERR0R_1_1_
Abnormal serve motor encoder
1. Motor is not turning
Possible cause:
bad EAC drive board
2. If motor is turning, then replace speed
Sensor
1. drive board
2. servo encoder
ERR0R_1_2_
Serve motor overheat ; speed limits
below 10KPH
1. Check temperature switch wiring
2. Adjust walk belt tension if motor is
overheat
3. Check whether walk belt & deck needs
replacement
4. if self-lubrication operate poorly, then
check the system
1. walk belt
ERROR_1_3_
Motor over loading
1. Rest and check
2. If issue persists, replace EAC drive
board
3. EAC drive board
ERROR_2_1_
IGBT over current
1. Rest and check
2. If issue persists, replace EAC drive
board
1. EAC drive board
ERR0R_2_2_
IGBT overheat
1. Rest and check
2. If issue persists, replace EAC drive
board
1. EAC drive board
ERROR_3_1_
Abnormal zero setting
of incline motor
1. Check wire connections
2. Replace drive board
3. Replace incline motor
1. EAC drive board
2. Incline motor
ERR0R_4_2_
Low voltage
1. Check if it is low voltage
2. Rearrange power wiring if power is
overloading.
ERROR_4_3_
High voltage
1. Check to see if it is high voltage
2. When treadmill is over tension, stop
using and waiting for normal voltage to
use.
ERROR_8_1_
communication error as First time
power on
1. Bad wire connections
2. Bad EAC drive board
1. EAC drive board
ERROR_8_2_
Power-on communication error
1. Reset and check
2. Check for proper grounding
3. If issue persists, replace EAC drive
board
1. EAC drive board
ERROR_8_3_
Interference issue of drive board 1. check wiring connection between control
board to drive board
1. drive board
Summary of Contents for T656
Page 1: ...T656 16 19 Repair Manual Electronic Date 2018 09 V1 0...
Page 3: ...1 1 Product Picture 1 1 1...
Page 4: ...1 2 Display T656 1 2 1...
Page 14: ...1 5 Wiring T656 self lubrication system 1 5 6 Lubricant motor VR Lubricant control system...
Page 15: ...1 5 Wiring energy saving board 1 5 7 To console EUP key board From Filer To Drive set...