4-6-1
Inspection and Measurement
Model : T615
Inspection point: Measuring VR voltage on the drive board
Inspection method: 1. Select the VDC setting on the multi-meter. Place probes on the VR set red-green wires.
2. If the VR voltage fluctuates widely, the VR is bad. Replace it.
Incline key
Drive board VR voltage
Incline position
0%
Red-green 1.20V
At red line (calibration point)
15%
Red-green 3.57V
Longest position
measure
Incline VR voltage
red-green
0%
1.20V
15%
3.57V
Incline red line