Inspection and Measurement
Inspection point: T611 transformer
Inspection method: 1. Inspect whether the transformer fuse has blown.
2. Measure transformer voltage.
3. Set the multi-meter to the AC setting. Place probes as follows:
4-2-1
Transformer fuse
Transformer connector
Transformer cables
Voltage
red-red or blue-blue (input
voltage)
110V (red)/220V(blue)
black-black (normal power)
12.5V
white-white (normal voltage)
12.5V
orange-orange (incline voltage)
29V
yellow-yellow (normal voltage)
11.5V
Summary of Contents for T611
Page 1: ...T611 Repair Manual Electronics...
Page 4: ...1 1 Product Picture T611 1 1 1...
Page 5: ...1 2 Overlay T611 1 2 1...
Page 7: ...1 3 Connections T611 Bridge Board 1 3 2 To Safety key board HTR board Soft key Bridge board...
Page 11: ...1 5 Connections T611 Bridge Board 1 5 2 To Safetykey board To HTR board To Display...