background image

4

2. SAfETy PRECAUTIONS  (CONTINUED)

 

● Check all cables and harnesses before each use. Should you find any 

signs of wear or defect in the cable or pulley assembly, immediately call 

SportsArt service for repairs or service. Should you find any signs of defect 

in the harness, contact the harness manufacturer.

 

● Ensure proper harness fit prior to and during use of the device. Please 

refer to the harness manufacturer’s instructions to ensure that the harness 

properly fits the patient.

 

Inproper grounding presents a shock hazard. If you have any ques-

tions, have a qualified electrician inspect the power supply outlet for proper 

grounding.

 

Only use the compressor that comes with the product, do not replace the 

compressor with any other compressors.

 

Never clean the compressor with liquids or solvents when cleaning. Dis-

connect the machine from the electricity supply by removing the plug and 

use a damp cloth only

 

The compressor must be placed on a stable surface

 

The compressor is designed for air compression only and must never be 

used for any other type of gas

 

Please do not attempt to modify the power cord. Adequate power supply 

must be provided. If the plug does not match the outlet, have a qualified 

electrician inspect and modify the power supply.

 

Before using this product, secure the safety straps in place. Hold the 

handles and stand erect.

 

After exercising, please remove the power cord from the power outlet. 

To avoid the risk of electrical shock, remove the power cord from the power 
outlet before cleaning or performing maintenance work.

Warning

 

If you feel any pain or abnormal sensation, STOP YOUR WORKOUT 

and consult your physician immediately. Work within your recommended 

exercise level. DO NOT work to exhaustion. Before beginning any exercise 

program, you should consult with your doctor. It is recommended that you 

undergo a complete physical examination. 

 

●  Only qualified technicians are permitted to contact electrical components, 

for instance, circuit boards. This product can carry an electrical charge even 

when the product is not in use and the power cord has been removed from 

the power source. After turning off the product, wait for five minutes before 

disconnecting the power cord from the power outlet. Only after taking such 

precautions should one remove the cover and contact components. 

Summary of Contents for ICARE E872MU

Page 1: ...Sports Art Industrial Co Ltd TUV CERT ISO 9001 9002 Certified Quality Products 2012 11 28 ICARE E872MU Body Weight Support System s Manual ...

Page 2: ...Body Weight Support System to the E872MA 8 STEP 5 Install the Compressor and Connections 10 4 OPERATE THE PRODUCT 11 OPERATION Lift Force Gauge and Lift Force Adjustment Knob 11 OPERATION Activation Switch and Seat Adjustment Switch 12 5 MAINTENANCE 13 Body Weight Support System Electrical Diagram 13 Body Weight Support System Pneumatic Diagram 13 Maintenance Schedule 14 6 LIST OF PARTS 15 7 LIST ...

Page 3: ...Fitness this product was built specifically for physical rehabilitation Before this product is assembled or operated we recommend that you familiarize yourself with this manual Understanding the correct methods of assembly and operation will help ensure that exercisers obtain their goals safely and successfully Parts of this assembly procedure will require three people ...

Page 4: ...ts Before turning off the power please let this physical rehabilitation elliptical trainer stop completely Do not unplug the power cord during operation Do not rock this product Please be careful in mounting and dismounting the unit If this product is damaged in any way stop operating it If this product has any issue or is broken notify the SportsArt service department DO NOT use accessories or pa...

Page 5: ... of gas Please do not attempt to modify the power cord Adequate power supply must be provided If the plug does not match the outlet have a qualified electrician inspect and modify the power supply Before using this product secure the safety straps in place Hold the handles and stand erect After exercising please remove the power cord from the power outlet To avoid the risk of electrical shock remo...

Page 6: ...to mast tube align bolt holes c Insert bolts washers and pins as shown Tighten bolts and insert snap rings Note the hardware shown below is not to scale d Check cable to ensure it is properly seated in the pulley groves IC1046 MAST ASSEMBLY IC1065 IC01 023 IC1048 IC1047 IC1059 BOOM ASSEMBLY 1 4 Lock Washer IC1046 4x 1 4 20 x 3 4 BHCS IC1065 1x Clevis Pin Ø1 4 x 3 4 IC1047 4x IC01 023 1x Boom Shear...

Page 7: ...6 STEP 2 Install the Leg Frame a Unpack both legs slide legs into frame b Connect air lines Firmly press loose end of hose into fitting with matching hose c Carefully tip unit upright FRAME LEG ...

Page 8: ...ch side of the mast assembly Add washer on opposite side and finger tighten nut b Slide hand rail into frame 5 16 18 x 2 75 Carriage Bolt IC1044 IC1040 IC1049 HAND RAIL IC1040 2x IC1049 2x 5 16 SAE Flat Washer IC1044 2x 5 16 18 Nylock Nut d Slightly lift hand rail until all holes align Insert flat head screws through middle hole e Insert carriage bolts into upper holes Add washers and nuts on oppo...

Page 9: ...t Support System forward over E872MA elliptical Line up Body Weight Support System hole with threaded boss on E872MA elliptical Warning Consult the manual and follow all assembly instructions carefully Please note that incorrect assembly may present a danger to the exerciser will damage the elliptical and void the warranty REMOVE ALIGN HOLES ...

Page 10: ...o people will need to lift the front of the elliptical while the third slides the overturn strap into place OVERTURN STRAP M10x1 5 Hex Bolt x 75mm IC1050 IC1043 IC1051 IC1088 IC1042 1 4 20 Nylock Nut IC1050 2X IC1043 2X IC1051 2X 3 8 USS Washer IC1042 2X 1 4 20 x 5 8 Carriage Bolt e Insert hardware as shown tighten f Slide on elliptical half base caps ...

Page 11: ...ting found on front of Body Weight Support System leg b Locate the 10ft extension cord One end will plug into the short section of cord hanging from the bottom on the Body Weight Support System c The other end of the extension cord can be plugged into the provided power strip Note It is required to plug the ICARE E872MA Elliptical power cord into a separate power source to guarantee the performanc...

Page 12: ...ing air pressure Typical applications require a lift force of less than 60 of the user weight Do not attempt to provide over 400lbs of support OPERATION Lift Force Adjustment Knob Turn clockwise to increase lifting force Turn counterclockwise to decrease lifting force Adjustments will be displayed simultaneously on lift force gauge The lifting force can be adjustedatanytime whethertheBodyWeightSup...

Page 13: ...ned to the on position the cable will begin to retract It will pull up with a force that correlates to the lift force gauge OPERATION Seat Adjustment Switch Used to raise or lower the seat Switch will automatically disable when upper or lower limit is reached LIFT FORCE GAUGE UNWEIGHT ACTIVATION SWITCH LIFT FORCE ADJUSTMENT KNOB SEAT ADJUSTMENT SWITCH ...

Page 14: ...0mm IC1017 1b BLOCK Qty Part Number A 1 IC1016 B 1 IC1012 C 3 IC1014 D 2 IC1015 Fitting Qty Part Number A 7 IC1024 B 1 IC1025 C 5 IC1026 D 2 IC1027 E 1 IC1028 F 1 IC1029 G 1 IC1030 H 1 IC1031 I 1 IC1032 J 2 IC1033 K 1 IC1034 Compressor Air Reservoir Cylinder A A J J A A A A K B C C C C A C D D E F G I EXHAUST H IC1002 IC1001 VALVE IC1022 GAGE IC1003 IC1009 CONTROL BOX IN OUT OUT NC REGULATOR IC102...

Page 15: ...proceeding as fig 6 make sure the tank is under pressure Air Tank Remove the condensate that has collected in the air tank To empty the tank put it under pressure take the compressor to a place where the water will not damage the floor tip the compressor slightly forward and open the tap Fig 7 Compressor effeciency Check possible connector slackening pressure hose wear screws tightening electric c...

Page 16: ...rame 1 IC01 205 Chair Lift Base 1 IC01 206 Control Box 1 IC01 207 Harness Spreader Bar 1 IC1001 Panther Silent Air Compressor 1 IC1002 Ø2 5 Double Acting Cylinder 1 IC1003 Ø1 5 Air Reservoir x 28 1 IC1004 Clevis Rod End 1 IC1004 02 Ø3 8 Clevis Pin Rod End 1 IC1005 Linear Rail 2 IC1006 Linear Carriage 8 IC1007 Cable Assembly 1 IC1007 02 Ø1 4 Clevis Pin Cable Assembly 1 IC1008 Nylon Pulley 2 IC1009 ...

Page 17: ...2 5 16 18 Nut Zinc 4 IC1054 Slide on Grip 21 2 IC1055 Rocker Switch SPDT 1 IC1056 Finish Plug Ø 5 8 2 IC1057 5 8 Hole Grommet 3 IC1058 Ø1 2 E Clip Zinc 6 IC1059 Ø3 8 E Clip Zinc 8 IC1063 Neoprene Rubber Edge 2 IC1064 Rectangle Tube Cap 2 IC1065 Clevis Pin Ø1 4 x 3 4 1 IC1068 Chain Size 1 4 Zinc 2 IC1069 Carabiner Ø3 8 Zinc 6 IC1070 Din Rail 1 IC1071 Web Sling 1 x 3 Eye Eye Nylon 1 IC1072 1 Ubolt w...

Page 18: ... IC1003 IC01 013 IC1056 IC1040 IC1041 IC1063 IC1043 IC1038 IC1045 IC1082 IC01 205 IC1042 IC1075 IC01 201 IC1042 IC1064 IC1043 IC01 030 IC01 024 IC01 019 IC1072 IC1052 IC1010 IC1007 02 IC1069 IC1069 IC1055 IC1022 IC1045 IC01 206 IC1076 IC01 033 IC1023 IC1009 IC1047 IC1044 IC1083 IC01 203 IC1065 IC1017 IC1057 IC1070 IC1006 IC1045 IC1039 IC1048 IC1016 IC1085 IC1032 IC1045 IC1005 IC01 031 IC1059 IC108...

Reviews: