Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Model: C575U
Malfunction: Unit will not start (alternator).
Circumstance: Start pedaling; the display shows no reaction.
Possible reasons: 1. Wires are not connected.
2. The drive board fuse has blown.
Troubleshooting: 1. Inspect wire and data cable connections.
2. Inspect the alternator. Do LED3 and LED6 on the drive board light
when you pedal?
3. Inspect whether F2 fuse on the drive board is burnt.
4. Replace the drive board as a test.
5. Inspect the display power LED and main
program IC.
3-1-1
Drive
Board
Display
board
Alternator
Alternator fuse 3A
Alternator
Display