background image

CARDIO 630

 

HEART RATE MONITOR

22

23

GUARANTEE CERTIFICATE – FOR PURCHASES MADE IN THE 
U.S.

If at any time within five (5) years from the purchase date of this 
product, it fails to perform properly because of defects in material 
or manufacturing, return it prepaid to: 

EB SPORT GROUP, 585 OAK 

RIDGE ROAD, HAZLETON, PA 18202

Complete this Guarantee Certificate and enclose it (or a copy of it) 
with the product. 

(PLEASE PRINT CLEARLY)

NAME

 

 

PHONE

 

STORE PURCHASED FROM

    

ADDRESS

  

 

 

DATE OF PURCHASE

 

CITY

   

 

 

PURCHASE PRICE

STATE

 

ZIP

                                                                     

PROBLEM WITH PRODUCT

REPLACEMENT

This product has been carefully designed, manufactured and packaged. If any 
parts are missing or damaged, please contact us at the address above and we 
will replace the unit at no charge. (Guarantee does not cover crystal or battery.)

©2011 Distributed by Sportline®, Hazleton, PA 18202

FOR PURCHASES MADE IN THE UK:

Should you experience problems with this item, please return it to the point of 
purchase.  This will not affect your statutory rights. Alternatively return it to the 
address shown below for a repair/replacement.

EB Brands UK, Berkeley Business Park, Wainwright Road, 

Worcester WR4 9FA

www.sportline.com

Distributed in the UK by EB Brands UK, Worcester WR4 9FA

WARRANTY

BATTERY SAFETY INFORMATION

 CAUTION – BATTERY SAFETY INFORMATION

•  

Non-rechargeable batteries are not to be recharged 

•  

Rechargeable batteries must be removed before recharging 

•  

Rechargeable batteries should only be recharged under 
adult supervision 

•  

Do not mix alkaline, standard (carbon-zinc), or recharge-
able (nickel-cadmium) batteries  

•  

Exhausted batteries are to be removed

•  

Do not mix old and new batteries

•  

Do not dispose of product or batteries in fi re; batteries may 
explode or leak

•  

If this product will not be used for an extended period of 
time, remove the batteries from the product

•  

The supply terminals are not to be short-circuited

•  

Batteries are to be inserted with correct polarity 

•  

Clean the battery contacts and also those of the product 
prior to battery installation

•  

As always, dispose of batteries in an eco-friendly manner

The purpose of the crossed-out wheelie bin symbol is to remind us 
that most electrical products, and batteries, contain trace elements 
(including Mercury – Hg, Cadmium – Cd and Lead – Pb) which could 
be harmful to our environment and therefore our health. We must all 
be careful to dispose of them responsibly in a specifi cally designated 
way – either using a collection scheme or into the correctly labeled 
civic amenity (NOT into general waste) – this will help your local 
authority to arrange to recycle or dispose of them in the appropriate 
manner.

SP1448IS01SPO.indd   22-23

SP1448IS01SPO.indd   22-23

6/10/11   12:20 PM

6/10/11   12:20 PM

Summary of Contents for CARDIO 630

Page 1: ...CARDIO 630 HEART RATE MONITOR USER GUIDE INSTRUCTION MANUAL SP1448IS01SPO Page Size 4 W x 5 5 H 6 6 11 SP1448IS01SPO indd 1 SP1448IS01SPO indd 1 6 10 11 12 19 PM 6 10 11 12 19 PM ...

Page 2: ... the instructions for the process important keys are shown indicating PRESS HOLD and PRESS The steps for the programming or operation are adjacent to the screen illustration Key points and important information are shown in highlighted blocks CUSTOMER SUPPORT If you have questions comments or need assistance with your Sportline Heart Rate Monitor you may contact Customer Sup port by calling 1 866 ...

Page 3: ... complete physical and to discuss your plans CAUTION Your watch is designed to be water resistant to a static pressure of 50 meters and can be worn while showering and light swimming However we recommend that extensive use of the unit in the water be avoided whenever possible Care should be taken not to press any keys while the unit is submerged as this can force moisture past the key seals and da...

Page 4: ...ible for compliance could void the user s authority to operate the product NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference in a residential installation This equipment generates uses and can radiate radio frequency energy...

Page 5: ...STOP RESET KEY S S R Start Stop Heart Rate Exercise Timer Start Stop Chronograph Increase setting values being adjusted in programming sequence PRESS HOLD Reset Exercise Timer Chronograph or Countdown Timer Turn Alarm ON or OFF in Alarm mode ADJUST Decrease setting values being adjusted in programming sequence Turn Alarm ON or OFF in Alarm mode LIGHT KEY Activates EL backlight system HEART RATE Ac...

Page 6: ...ing the electrodes with saliva or ECG conductive gel can speed up this process CODING THE CHEST STRAP TRANSMITTER WEARING THE CHEST STRAP TRANSMITTER ELECTRODES 3 2 4 The Sportline Cardio 630 features a coded chest strap trans mitter with multiple channels to eliminate interference from other heart rate monitors when exercising in close proximity to other people such as a group fitness class The mo...

Page 7: ...PRESSING the MODE key You may access Heart Rate Exercise mode by PRESSING the HEART RATE key in any operating mode MAIN OPERATING MODES MAIN OPERATING MODES PRESS HEART RATE to enter Heart Rate Exercise mode To exit Heart Rate Exercise mode PRESS HEART RATE or MODE TIME OF DAY CHRONOGRAPH ALARM SP1448IS01SPO indd 12 13 SP1448IS01SPO indd 12 13 6 10 11 12 19 PM 6 10 11 12 19 PM ...

Page 8: ...RT STOP RESET S S R to increase or ADJUST ADJ to decrease You set the information and advance to the next field by PRESSING MODE The display reads Saved when this sequence is complete The monitor is then ready for use You may exit the Programming Sequence at any time by PRESSING HOLDING the MODE key PRESS HOLD the MODE key In Time of Day mode to enter the Programming Sequence SETTING TIME CALENDAR ...

Page 9: ...lt as instructed in the previous section CODING THE CHEST STRAP TRANSMITTER 2 PRESS the HEART RATE key to access Heart Rate Exercise Timer NOTE you must be wearing chest transmitter strap to read heart rate 3 PRESS START STOP RESET S S R to acquire heart rate and begin timing You may access other modes by PRESSING MODE or HEART RATE NOTE heart rate data will still be recorded 4 PRESS S S R to stop...

Page 10: ...ilable CAUSE Chest strap is not contacting with skin SOLUTION Make sure the chest strap is firmly over the chest and the Watch is securely on wrist CAUSE Dead or flaking skin on chest SOLUTION Rub off excessive dead skin with a towel CAUSE A thin layer of body grease insulates the ECG signal pre venting the Chest Strap or Watch from detecting ECG heart rate SOLUTION Wipe chest wrist and the back of ...

Page 11: ...remains fully water resistant Failure to properly replace the battery and correctly seal the unit may cause the unit to become damaged and may void the warranty The Sportline Cardio 630 watch uses a single CR2032 3v lithium battery Battery replacement will be required from time to time and should occur when 1 The display fades in part or completely 2 The heart rate function will not activate 3 Bac...

Page 12: ...NFORMATION CAUTION BATTERY SAFETY INFORMATION Non rechargeable batteries are not to be recharged Rechargeable batteries must be removed before recharging Rechargeable batteries should only be recharged under adult supervision Do not mix alkaline standard carbon zinc or recharge able nickel cadmium batteries Exhausted batteries are to be removed Do not mix old and new batteries Do not dispose of pr...

Page 13: ...LINE a division of EB Sport Group Yonkers NY 10701 Distributed in the UK by EB Brands UK Worcester WR4 9FA All Rights Reserved 2011 SP1448IS01SPO CARDIO 630 HEART RATE MONITOR SP1448IS01SPO indd 24 SP1448IS01SPO indd 24 6 10 11 12 20 PM 6 10 11 12 20 PM ...

Reviews: