Load Cell Calibration
Load cell calibration consists of applying a known weight on a calibration arm at the brake. But first of
all, the cell has to be “zeroed” when it has no weight. Then the program is able to use the difference
from the digital reading between the no-load condition and the loaded condition to perform the
calibration.