SP6 Installation and Setup V0.91
Sportdevices © 2019
20/NOV/2019
3.4.2.2
Panic Button
Panic Button / Emergency Stop is a Normally Open Switch that can be connected to the “panic”
terminals. Polarity does not matter. When pressed the SP6 will apply a pre-defined brake torque to the
rollers until they are stopped (switch can be released before the rollers are stopped)
3.4.2.3
PWM outputs
PWM signals are replicated at back side to ease the installation of SP6 and PWS, in order to avoid using
the “T-cables” that split the signal from 5-pin connectors between hall sensor and PWS (as in SP5)
1 – OUT1 (F1)
2– OUT (R1)
3– OUT3 (F2)
4 – OUT4 (R2)
5 – GND
3.4.2.4
Counter Input
Low Speed counter CNT (typically for detonation counter)
1 – 12V (100 ma max)
2– Input (0-5V, max 1000 Hz)
3– GND
3.4.2.5
Servo Output
Servo Output is internally configurable to RC pulse (PPM) or PWM / analog
1 –6V (4A max)
2– Output. Configurable to PPM, PWM, analog (0-5V)
3– GND
3.4.2.6
Air Speed
Airspeed output: PWM 0-5 volt / 2.4 KHz as a function of roller speed
1 –Output (0-5V), configurable as PWM or analog
2– GND
3.4.2.7
Analog inputs
SP6 provides up to 8 analog inputs with a 12-bit converter
1-5V
10-5V
2-AIN1 / LAMBDA1
11-AIN5
3-GND
12-GND
4-AIN2 / LAMBDA2
13-AIN6
5-GND
14-GND
6-AIN3
15-AIN7
7-GND
16-GND
8-AIN4
17-AIN8
9-GND
18-GND
3.4.2.8
Thermocouple Inputs
SP6 includes 8 differential inputs with cold-juntion compensation to read thermocouples type K
Bottom Row
Top Row
1 – TC1+
1 – TC5+
2 – TC1-
2 – TC5-
3 – TC2+
3 – TC6+
4 – TC2-
4 – TC6-
5 – TC3+
5 – TC7+
6 – TC3-
6 – TC7-
7 – TC4+
7 – TC8+
8 – TC4-
8 – TC8-