Liquid Controls
Sponsler, Inc.
IT400 Remote Totalizer & Rate Indicator
Page: 21
DOC#:
MN-IT400-R2c.doc
useful when the data is captured to a computer and later imported into a data analysis
program or database.
DB format Disabled
– Pretty-Print format. This format will list data on separate lines,
preceded by the name of the data and followed by the given units of measure. This format
is more useful for ticket printing and human readability. The time/date that will be logged
when this setting is enabled will be in the format: Fri Aug 12 2005 12:36:56 GMT-0400
!
– Activation timer period. Only available if
!
is enabled. Sets the number of
seconds between timer triggered datalog activations.
Note:
If the power mode is set to 5, the activation timer period will be rounded down to the
nearest even number.
17. Real-Time Clock
The real time clock menu allows the viewing and setting of the internal real time
clock. Pressing
Select
toggles between the current date and time (the next two
submenu items). Holding
Select
for more than 3 seconds allows editing.
17.1 Current Time
Allows the setting of the time portion of the real time clock. The current time is set by holding
Select
for more than 3 seconds. Prompts for time zone (
4
), hour (
5
), minute
(
!
), and second (
*
) are displayed. The internal time will resume the instant
Enter
is pressed after entering seconds.
17.2 Current Date
Allows the setting of the date portion of the real time clock. The current date is set
by holding
Select
for more than 3 seconds. Prompts for year (
), month (
!
5
), and day (
)
are displayed. Setting the date will not affect the time portion of the real time clock.
18. Warnings
The editing of the system warnings used for the on-screen warnings and the alarm
set points (if purchased) is allowed when
is selected here. Temperature limits
and temperature delay are only available if temperature compensation is enabled or temperature is
enabled in the alarm output, or the datalogger.
18.1 Edit Low Flow Limit
The minimum valid flow rate before triggering a low flow warning.
Note:
In order to have the rate display show a low flow warning (
) at zero flow,
set this output low setting to
.
(
.
18.2 Edit High Flow Limit
The maximum valid flow rate before triggering a high flow warning.
18.3 Edit Low Temperature Limit
The minimum valid temperature before triggering a low temperature warning.
(,6 &6 &
(
.
-
.
,
.
.
)
"
1111111
.
,
) 2